Objectiveto present a retrospective analysis on the clinical-functional results and complications among patients with rotator cuff arthropathy (RCA) who underwent reverse arthroplasty of the shoulder.Methodspatients with a diagnosis of RCA associated with pseudoparalysis of anterior elevation who underwent reverse arthroplasty of the shoulder with a minimum follow-up of one year were selected.Resultspreoperative information was gathered from our shoulder and elbow arthroplasty register, comprising age, sex, laterality, history of previous procedures, Constant's functional scores and the preoperative range of motion as described in the protocol of the American Academy of Shoulder and Elbow Surgery (ASES). After a mean follow-up of 44 months, 17 patients (94%) were satisfied with the result from the procedure.Conclusionreverse arthroplasty for treating RCA in patients with pseudoparalysis of the shoulder was shown to be effective in achieving a statistically significant improvement in range of motion regarding anterior flexion and abduction. However, in this series, there was no improvement in range of motion regarding external and internal rotation. Reverse arthroplasty is a procedure that reestablishes shoulder joint function in patients who previously did not present any therapeutic possibilities.
Background
Although biceps tenodesis has been widely used to treat its pathologies, few studies looked at the objective evaluation of elbow strength after this procedure. The purpose of this study is to clinically evaluate patients submitted to long head of the biceps (LHB) tenodesis with interference screws through an intra-articular approach and analyze the results of an isokinetic test to measure elbow flexion and forearm supination strengths.
Methods
Patients who had biceps tenodesis were included in the study if they had a minimum follow-up of 24 months. Patients were excluded if they had concomitant irreparable cuff tears or previous or current contralateral shoulder pain or weakness. Postoperative evaluation was based on University of California–Los Angeles (UCLA) shoulder score and on measurements of elbow flexion and supination strength, using an isokinetic dynamometer. Tests were conducted in both arms, with velocity set at 60º/s with 5 concentric-concentric repetitions.
Results
Thirty-three patients were included and the most common concomitant diagnosis were rotator cuff tear (69%) and superior labrum anterior to posterior (SLAP) lesions (28%). The average UCLA score improved from 15.1 preoperatively to 31.9 in the final follow-up (
P
< .001). Isokinetic tests showed no difference in peak torque between the upper limbs. One patient had residual pain in the biceps groove. None of the patients had Popeye deformity. UCLA score and follow-up length did not demonstrate correlation with peak torque.
Conclusion
Arthroscopic proximal biceps tenodesis with interference screw, close to the articular margin, yielded good clinical results. Isokinetic tests revealed no difference to the contralateral side in peak torque for both supination and elbow flexion.
Resumo
Objetivos A falha do componente glenoidal é a principal causa de revisão da artroplastia total do ombro (ATO) e sua frequência parece ser influenciada pelo design do componente. O objetivo deste estudo foi a avaliação clínica e radiográfica (através de raios X e tomografia computadorizada) dos resultados da ATO com componente glenoidal minimamente cimentado.
Métodos O presente trabalho analisou ATOs realizadas com componente glenoidal Anchor Peg (DuPuy Synthes, Warsaw, IN, EUA) minimamente cimentado entre 2008 e 2013. Por um período mínimo de acompanhamento de 24 meses, escores segundo critérios da University of California at Los Angeles (UCLA) e imagens padronizadas de radiografia simples e tomografia computadorizada foram analisadas. A presença de osso entre as aletas do pino do componente central, que é um indicador de sua integração, foi avaliada nas imagens, bem como a presença de linhas radiotransparentes ao redor do componente glenoidal.
Resultados Dezenove ombros de 17 pacientes foram avaliados. De acordo com o escore da UCLA, os resultados clínicos foram satisfatórios em 74% dos casos e moderados em 21% dos casos. O resultado foi ruim em um paciente. A integração de componentes foi observada em 58% dos pacientes, sendo total em 42% e parcial em 16% dos casos. Linhas radiotransparentes foram observadas em 52% dos pacientes. Nenhuma relação entre a integração de componentes e os resultados clínicos foi detectada.
Conclusão A maioria dos pacientes submetidos à ATO com componente glenoidal minimamente cimentado apresentou resultados clínicos satisfatórios. Linhas radiotransparentes ao redor do componente glenoidal são comuns, mas não interferem nos resultados clínicos
Nível de evidência IV. Série de caso. Estudo terapêutico.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.