The stretched exponential model fits better with signal intensity measurements from both lesion and glandular tissue ROIs. Although the DDC ratio estimated by using the model shows a higher diagnostic accuracy than the ADC ratio, lesion DDC, and ADC, it is not statistically significant. J. Magn. Reson. Imaging 2016;44:1633-1641.
Density assessment and lesion localization in breast MRI require accurate segmentation of breast tissues. A fast, computerized algorithm for volumetric breast segmentation, suitable for multi-centre data, has been developed, employing 3D bias-corrected fuzzy c-means clustering and morphological operations. The full breast extent is determined on T1-weighted images without prior information concerning breast anatomy. Left and right breasts are identified separately using automatic detection of the midsternum. Statistical analysis of breast volumes from eighty-two women scanned in a UK multi-centre study of MRI screening shows that the segmentation algorithm performs well when compared with manually corrected segmentation, with high relative overlap (RO), high true-positive volume fraction (TPVF) and low false-positive volume fraction (FPVF), and has an overall performance of RO 0.94 ± 0.05, TPVF 0.97 ± 0.03 and FPVF 0.04 ± 0.06, respectively (training: 0.93 ± 0.05, 0.97 ± 0.03 and 0.04 ± 0.06; test: 0.94 ± 0.05, 0.98 ± 0.02 and 0.05 ± 0.07).
Cellular neural networks (CNNs) are massively parallel cellular structures with learning abilities. They can be used to realize complex image processing applications efficiently and in almost real time. In this preliminary study, we propose a novel, robust, and fully automated system based on CNNs to facilitate lesion localization in contrast-enhanced MR mammography, a difficult task requiring the processing of a large number of images with attention paid to minute details. The data set consists of 1170 slices containing one precontrast and five postcontrast bilateral axial MR mammograms from 39 patients with 37 malignant and 39 benign mass lesions acquired using a 1.5 Tesla MR scanner with the following parameters: 3D FLASH sequence, TR/TE 9.80/4.76 ms, flip angle 250, slice thickness 2.5 mm, and 0.625 x 0.625 mm2 in-plane resolution. Six hundred slices with 21 benign and 25 malignant lesions of this set are used for training the CNNs; the remaining data are used for test purposes. The breast region of interest is first segmented from precontrast images using four 2D CNNs connected in cascade, specially designed to minimize false detections due to muscles, heart, lungs, and thoracic cavity. To identify deceptively enhancing regions, a 3D nMITR map of the segmented breast is computed and converted into binary form. During this process tissues that have low degrees of enhancements are discarded. To boost lesions, this binary image is processed by a 3D CNN with a control template consisting of three layers of 11 x 11 cells and a fuzzy c-partitioning output function. A set of decision rules extracted empirically from the training data set based on volume and 3D eccentricity features is used to make final decisions and localize lesions. The segmentation algorithm performs well with high average precision, high true positive volume fraction, and low false positive volume fraction with an overall performance of 0.93 +/- 0.05, 0.96 +/- 0.04, and 0.03 +/- 0.05, respectively (training: 0.93 +/- 0.04, 0.94 +/- 0.04, and 0.02 +/- 0.03; test: 0.93 +/- 0.05, 0.97 +/- 0.03, and 0.05 +/- 0.06). The lesion detection performance of the system is quite satisfactory; for the training data set the maximum detection sensitivity is 100% with false-positive detections of 0.28/lesion, 0.09/slice, and 0.65/case; for the test data set the maximum detection sensitivity is 97% with false-positive detections of 0.43/lesion, 0.11/slice, and 0.68/case. On the average, for a detection sensitivity of 99%, the overall performance of the system is 0.34/lesion, 0.10/slice, and 0.67/case. The system introduced does not require prior information concerning breast anatomy; it is robust and exceptionally effective for detecting breast lesions. The use of CNNs, fuzzy c-partitioning, volume, and 3D eccentricity criteria reduces false-positive detections due to artifacts caused by highly enhanced blood vessels, nipples, and normal parenchyma and artifacts from vascularized tissues in the chest wall due to oversegmentation. We hope that this system will fa...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.