This article presents the results of evaluating the changes in peri-implant soft tissue dimensions associated with immediate implant placement into anterior postextraction sockets for four treatment groups: no BGPR (no bone graft, no provisional restoration), PR (no bone graft, provisional restoration), BG (bone graft, no provisional restoration), and BGPR (bone graft, provisional restoration). The vertical distance of the peri-implant soft tissue was greater for grafted sites than for nongrafted ones (2.72 mm vs 2.29 mm, P < .06). The facial soft tissue thickness at the gingival third also was greater for grafted than for nongrafted sites (2.90 mm vs 2.28 mm, P < .008) and for sites with provisional restorations compared to sites without them (2.81 mm vs 2.37 mm, P < .06), respectively. The net gain in soft tissue height and thickness was about 1 mm. The increases in vertical and horizontal dimensions for grafted sites were between 0.5 and 1.0 mm, as compared to sites with no bone graft and no provisional restoration.
Placing an absorbable membrane, bone graft, and custom-healing abutment at the time of flapless anterior tooth extraction and immediate implant placement into a socket with a labial osseous dehiscence is a viable clinical technique to reconstitute the absence of the labial bone plate.
This paper presents the results of a prospective study on the clinical effect of grafting the buccal gap with platform switching, following flapless tooth extraction and immediate implant placement and provisional restoration, on (1) alterations in buccolingual ridge dimension and (2) midfacial peri-implant soft tissue thickness. Fifty-six patients were placed in one of four treatment groups: (1) a non-platform-switching implant (Non-PS, n = 14); (2) a non-platform-switching implant and bone graft (BG/Non-PS, n = 14); (3) a platform-switching implant (PS, n = 15); and (4) a platform-switching implant and bone graft (BG/PS, n = 13). Buccolingual ridge dimensional change and peri-implant soft tissue thickness at 2 mm below the free gingival margin were measured. Both PS and BG/PS groups showed an increase in buccolingual dimension compared to the contralateral natural tooth site as well as peri-implant soft tissue thickness of > 2.5 mm, clinically. Platform switching was associated with significantly greater midfacial soft tissue thickness than bone grafting (mean ± standard deviation: 2.17 ± 0.04 for Non-PS and 3.55 ± 0.14 for PS). Using platform-switched implants, in conjunction with immediate implant placement and immediate provisional restoration, was associated with a significantly greater stability of ridge dimension and peri-implant soft tissue thickness than using non-platform-switched implants when measured 12 months after placement of the final restoration. Platform switching may help achieve preservation of ridge dimension and enhance the stability of peri-implant soft tissue following immediate implant placement and provisional restoration without bone grafting. Further research is required to assess the long-term outcome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.