The underground temperature distribution and variation are important for the development and utilization of shallow geothermal energy and underground space. In this paper, a remote ground temperature monitoring system was established in Chongqing, located in southwest China and the ground temperature distribution and its variation with seasons of the 100m underground depth was measured from June 2010 to June 2011. The results show that, in the typical geo-structure of Chongqing, the variational ground temperature zone is from 0m to 10m, where the ground temperature is strongly affected by the change of ambient temperature. Below 11m depth, the ground temperature does not change with seasons, i.e., it is the constant ground temperature zone. In the constant temperature zone below 40 meter depth, the geothermal gradient is about 0.02°C/m. Baggs’s empirical formula was applied to predict the ground temperature distribution history at different ground depths. The results show a good agreement with the measured data.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.