An interlaboratory round robin study was conducted on the tensile strength of SiC‐SiC ceramic matrix composite (CMC) tubular test specimens at room temperature with the objective of expanding the database of mechanical properties of nuclear grade SiC‐SiC and establishing the precision and bias statement for standard test method ASTM C1773. The mechanical properties statistics from the round robin study and the precision statistics and precision statement are presented herein. The data show reasonable consistency across the laboratories, indicating that the current C1773‐13 ASTM standard is adequate for testing ceramic fiber reinforced ceramic matrix composite tubular test specimen. It was found that the distribution of ultimate tensile strength data was best described with a two‐parameter Weibull distribution, while a lognormal distribution provided a good description of the distribution of proportional limit stress data.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.