The objective of this study is to develop nuclear heating measurement methods in Zero Power experimental reactors. This paper presents the analysis of Thermo-Luminescent Detector (TLD) and Optically Stimulated Luminescent Detectors (OSLD) experiments in the UO core of the MINERVE research reactor at the CEA Cadarache.The experimental sources of uncertainties on the gamma dose have been reduced by using the optimum conditions of charged particle equilibrium (CPE) of the calibration step for each individual TLD.The interpretation of these measurements needs to take into account calculation of cavity correction factors, related to calibration and irradiation configurations, as well as neutron corrections calculations. These calculations are based on Monte Carlo simulations of neutron-gamma and gamma-electron transport coupled particles. TLD and OSLD are positioned inside aluminum pillboxes.The comparison between calculated and measured integral gamma-ray absorbed doses using TLD, shows that calculation slightly overestimates the measurement with a calculation versus experiment (C/E) ratio value equal to 1.05 5.3%. By using OSLD, the calculation slightly underestimates the measurement with a C/E value equal to 0.96 7.0% .
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.