In this article, we demonstrated the unexpected reduction of optical zone diameter in myopic keratomileusis and its causes. Mathematical evaluation of optical zone diameter was made possible through a module added to a computer program. Optical zone diameter was reduced more in smaller corrections than in higher corrections. Practical measurements were parallel to mathematical expectations except in some small corrections between -4.00 and -6.00 diopters, where it was even more reduced than calculated. We were able to enlarge the optical zone diameter using the same computer module. Refract Corneal Surg 1991:7:161-1 66.)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.