X-ray diagnosis is a crucial aspect of nuclear experiments, as many fields in physical research require X-ray analysis. The X-ray diode (XRD) detector is commonly used in X-ray detection due to its short response time, necessitating a high-speed readout circuit. In this paper, we present the design of an X-ray diagnosis system with readout electronics utilizing time-interleaved analog-to-digital converters (TIADC). One of the challenging problems in TIADC is the mismatch problem between channels, which severely reduces the system's performance. We propose a fast calibration method for adjusting the mismatch, significantly improving the acquisition system's performance. We have implemented an adapted module to perform the calibration in real-time. In performance tests, the proposed method is shown to be as effective as other methods, and the electronic performance of the system meets the diagnosis requirements. The X-ray signals acquired by this system exhibit high quality in the inertial confinement fusion (ICF) of the SG-III laser facility.
A compact and integrated neutron-gamma discrimination spectrometer that could be utilized for personal dosimetry and emergency response is urgently required. In this study, based on a CLYC scintillator coupled to silicon photomultiplier(SiPM) arrays, we designed a stand-alone, hand-held neutron-gamma discrimination spectrometer. After the analog-to-digital converter (ADC) digitizes the analog signal from the detector, the data is transmitted to a FPGA processor for online real-time processing, and then transmitted to a microcontroller through the serial peripheral interface(SPI) protocol, and the current detection result is displayed in real-time on the touch screen. By using the pulse signal discrimination(PSD) method, the spectrometer can simultaneously measure the spectrum of neutron and gamma events, with a resolution of 8.8% (at 1274.5 keV) and excellent linearity. The figure of merit (FOM) is 2.32 with optimized PSD parameters. The experimental results show that the spectrometer integrates the upper computer and detector, with real-time performance, portability and excellent neutron-gamma resolution. Online operation is realized through the touch screen, which greatly facilitates the real-time detection of radiation in the field environment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.