Purpose:To systematically review randomized controlled clinical trials (RCTs) reporting on the long-term survival and failure rates, as well as the complications of short implants (≤6 mm) versus longer implants (>6 mm) in posterior jaw areas. Materials and Methods:Electronic and manual searches were conducted to identify studies, specifically RCTs, reporting on short dental implants (≤6 mm) and their survival and complication rates compared with implants longer than 6 mm. Secondary outcomes analyzed were marginal bone loss and prosthesis survival rates.Results: Ten RCTs fulfilled the inclusion criteria and featured a total of 637 short (≤6 mm) implants placed in 392 patients, while 653 standard implants (>6 mm) were inserted in 383 patients. The short implant survival rate ranged from 86.7% to 100%, whereas standard implant survival rate ranged from 95% to 100% with a follow-up from 1 to 5 years. The risk ratio (RR) for short implant failure compared to standard implants was 1.29 (95% CI: 0.67, 2.50, p = 0.45), demonstrating that overall, short implants presented higher risk of failure compared to longer implants. The heterogeneity test did not reach statistical significance (p = 0.67), suggesting low betweenstudy heterogeneity. The prosthesis survival rates from the short implant groups ranged from 90% to 100% and from 95% to 100% for longer implant groups, respectively.Conclusion: Short implants (≤6 mm) were found to have higher variability and lower predictability in survival rates compared to longer implants (>6 mm) after periods of 1-5 years in function. The mean survival rate was 96% (range: 86.7%-100%) for short implants, and 98% (range 95%-100%) for longer implants. Based on the quantity and quality of the evidence provided by 10 RCTs, short implants with ≤6 mm length should be carefully selected because they may present a greater risk for failure compared to implants longer than 6 mm. K E Y W O R D S dental implants, short dental implantsThis is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
Objectives: Working Group 5 was assigned the task to review the current knowledge in the area of digital technologies. Focused questions on accuracy of linear measurements when using CBCT, digital vs. conventional implant planning, using digital vs.conventional impressions and assessing the accuracy of static computer-aided implant surgery (s-CAIS) and patient-related outcome measurements when using s-CAIS were addressed. Materials and methods:The literature was systematically searched, and in total, 232 articles were selected and critically reviewed following PRISMA guidelines. Four systematic reviews were produced in the four subject areas and amply discussed in the group. After emendation, they were presented to the plenary where after further modification, they were accepted.Results: Static computer-aided surgery (s-CAIS), in terms of pain & discomfort, economics and intraoperative complications, is beneficial compared with conventional implant surgery. When using s-CAIS in partially edentulous cases, a higher level of accuracy can be achieved when compared to fully edentulous cases. When using an intraoral scanner in edentulous cases, the results are dependent on the protocol that has been followed. The accuracy of measurements on CBCT scans is software dependent. Conclusions:Because the precision intraoral scans and of measurements on CBCT scans and is not high enough to allow for the required accuracy, s-CAIS should be considered as an additional tool for comprehensive diagnosis, treatment planning, and surgical procedures. Flapless s-CAIS can lead to implant placement outside of the zone of keratinized mucosa and thus must be executed with utmost care. K E Y W O R D Saccuracy, computer-aided surgery, cone beam computed tomography, intraoral scans, oral implantology, patient-reported outcome measures sidering standardized conditions, and (b) it is crucial to address the software version and used scan protocol for further studies to create a reliable database for accurate statistical analyses.Although in clinical practice, single unit restorations are being performed using a digital workflow, there is a need for further research to conclude if it is a predictable and reliable procedure when compared to the conventional workflow.• There is a lack of literature about the accuracy of different intraoral scan bodies in terms of geometry, dimension, material, and surface characteristics. More studies regarding these aspects should be conducted.• In studies using scan bodies, design, and characteristics should be defined to make studies comparable.• Regarding multiple implant-supported restorations for partially dentate or edentulous cases, different scanning protocols should be developed and compared.The influence of distance between scan bodies, length and geometry of the edentulous span, mucosal morphology, and on the accuracy of digital impressions should be studied.The aim of this systematic review was to identify studies that assessed the accuracy of linear measurements of bone dimensions related to implant...
A host molecule, capable of freely adopting P or M helicity, is described for molecular recognition and chirality sensing. The host, consisting of a biphenol core, binds chiral amines via hydrogen-bonding interactions. The diastereomeric complex will favor either P or M helicity as a result of minimizing steric interactions of the guest molecule with the binding cavity of the host, resulting in a detectable exciton-coupled circular dichroic spectrum. A working model is proposed that enables non-empirical prediction of the chirality of the bound amine.
Implant overdentures supported by soldered gold bars or milled CAD/CAM Ti-bars are a successful treatment modality but require regular maintenance service. These short-term observations support the hypothesis that CAD/CAM Ti-bars reduce technical complications. Fracture location indicated that the titanium thickness around the screw-access hole should be increased.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.