Objective: The purpose of this study was to determine the prevalence, height, location and morphology of maxillary sinus septa in dentate, partially dentate and edentulous adults as well as in mixed dentition children using cone beam computed tomography (CBCT) for maxillary sinus surgical interventions. Subjects and Methods: Five hundred and fifty-four sides in the CBCT scans of 272 patients (30 children and 242 adults) were retrospectively analyzed. The prevalence, location and morphology were assessed in axial, sagittal, cross-sectional and panoramic 3-dimensional images. The height of septa was measured with the angle between the direction of the septum and median palatine suture. The differences among age, localization and measurements were statistically analyzed. Results: The prevalence of maxillary sinus segments with septa was 58%. There were a total of 13 (3.2%) septa of completely edentulous (CE), 198 (53.9%) septa of edentate and 14 (3.8%) septa of the mixed dentition maxillary segments. The location of septa observed in all study groups demonstrated a greater prevalence (69.1%) in the middle region than in the anterior and posterior regions. No statistically significant differences were observed with regard to gender or age, for septum height (p > 0.05). However, maxillary sinus septa are higher in partially edentulous patients than edentate and CE ones (p < 0.05). Conclusion: Septa of various heights and courses developed in all parts of the maxillary sinus, therefore to prevent possible complications during sinus surgery, extensive evaluation with an appropriate radiographic technique was indispensable.
The results reported in this case show that the healing of mucous membrane pemphigoid was achieved when LLLT was used as an adjunct to the application of a local corticosteroid.
Er,Cr:YSGG laser is a rising treatment option for dentine hypersensitivity (DH). However, there is no data available concerning the scanning electron microscope (SEM) evaluation of the clinical application of Er,Cr:YSGG laser in the treatment of DH. The aim of this study was to evaluate and compare the desensitising and tubule occlusion effects of Er,Cr:YSGG laser with different power settings. Twenty patients (60 teeth) participated in this study. For each patient, teeth were randomised to 3 groups. In groups 1 and 2, patients were treated with Er,Cr:YSGG laser at 0.25 and 0.5 W, respectively. In control group, same laser was applied without laser emission. DH was assessed for all groups with a visual analogue scale (VAS). When compared with the baseline data and control group, in both active treatment groups laser irradiation provided a desensitising effect immediately after treatment (P < 0.001). In group 2, VAS scores were significantly lower than group 1. The tubule diameters in the both laser groups were significantly smaller than the control group (P < 0.01). When group 1 compared with group 2, group 2 showed significantly smaller tubule diameters (P < 0.001). Both 0.25 and 0.5 W laser irradiation were effective for the treatment of DH; however, 0.5 W laser irradiation showed best results for the decrease in VAS scores. The SEM findings of the reduction in number/patency of dentine tubules seem to be related to the clinical findings, which were associated with improvement in treatment efficacy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.