To characterize a functional assay for circulating fibrinogen based on rotational thrombelastography. Maximum clot firmness was determined by rotational thrombelastography in normal human plasma pool, fibrinogen-deficient plasma pool, normal whole blood, and individual plasma samples from 17 patients with fibrinogen deficiency. Plasma samples spiked with varying concentrations of exogenous fibrinogen were also measured. Results were compared with enzyme-linked immunosorbent assay and Clauss assay. The impact of sample freezing and filtration and use of cytochalasin D were also investigated. Over the tested range of 0-3 mg/ml added exogenous fibrinogen, the maximum clot firmness standard curve for determination of fibrinogen in plasma pools (n = 7) was linear (r2 = 0.97). Maximum clot firmness was highly linearly correlated both with Clauss assay (r2 = 0.93) and enzyme-linked immunosorbent assay (r2 = 0.95). In unspiked plasma samples from individual patients with fibrinogen deficiency, fibrinogen was undetectable by rotational thromboelastography. By all evaluated methods, the response to spiking with fibrinogen in such samples coincided closely in patients with afibrinogenemia and hypofibrinogenemia. In dysfibrinogenemia, smaller Clauss assay responses to spiking were observed, whereas the enzyme-linked immunosorbent assay response was variable. Maximum clot firmness was the only evaluated method of fibrinogen assessment to yield consistent results across all categories of fibrinogen deficiency. These in-vitro results suggest the potential clinical utility of rotational thromboelastography as a versatile method for monitoring the response to fibrinogen concentrate among patients with fibrinogen deficiency. Clinical investigations using rotational thromboelastography after in-vivo fibrinogen administration to patients with congenital fibrinogen deficiency are warranted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.