A new non-invasive method for investigating total coronary blood supply is presented. This method is based on the principle of indicator dilution of a radio-nuclide bolus (99Tc), requiring a scintillation camera with high sensitivity and high picture resolution. The first findings obtained from 83 patients are shown. With 4.61 +/- 1.19% of cardiac output the mean values of the rates of coronary perfusion obtained at rest in subjects with a normal heart differed significantly from those obtained for patients with certain coronary occlusions (8.18 +/- 3.99% of cardiac output) and from those obtained for hypertensive patients (Stages I-III). Double examinations carried out on 20 patients yielded an adequate reproducibility. The mean deviation of the double examinations from one another was 16%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.