Are short femoral nails superior to the sliding hip screw? A meta-analysis of 24 studies involving 3,279 fractures Abstract The purpose of this meta-analysis was to compare the fixation outcome between the sliding hip screw (SHS) and intramedullary nails (IMN) in stable and unstable extracapsular proximal femoral fractures. All randomised controlled studies comparing IMNs with a SHS were considered for inclusion. Data was independently extracted and trial methodology assessed. Twentyfour randomised trials involving 3,202 patients with 3,279 fractures were included. Pooled results gave no statistically significant difference in the cut-out rate between the IMN and SHS (41/1,556 vs 37/1,626; relative risk 1.19; 95% confidence interval 0.78-1.82). Total failure rate (1,03/1,495 and 58/1,565, relative risk 1.83; 95% confidence interval 1.35-2.50) and re-operation rate (57/1,357 and 35/1,415, relative risk 1.63; 95% confidence interval 1.11-2.40) were greater with the IMN compared with the SHS. There was no evidence for a reduced failure rate with IMN in unstable trochanteric fractures.Résumé Le but de cette méta-analyse était de comparer le résultat de la fixation par vis glissante et clou centromé-dullaire dans les fractures extracapsulaires fémorales proximales stables et instables. Toutes les études randomisées et contrôlées qui comparent des clous centromédul-laires avec une vis glissante ont été considérées pour l'inclusion. Les données ont été extraites indépendamment, et la méthodologie de l'étude étudiée. 24 essais randomisés qui concernent 3,202 malades avec 3,279 fractures ont été inclus. Les résultats mis en commun n'ont donné aucune différence statistiquement notable entre le clou centromé-dullaire et la vis glissante (41/1,556 vs 37/1,626; risque relatif 1.19; 95% intervalle de confidence 0.78-1.82). Le taux d'échec total (103/1,495 vs 58/1,565, risque relatif 1.83; 95% intervalle de confiance 1.35-2.50) et tle aux de la ré -opération (57/1,357 vs 35/1,415, risque relatif 1.63; 95% intervalle de confiance 1.11-2.40) étaient plus grands avec le clou centromédullaire comparé a la vis glissante. Il n'y avait aucune preuve qu'il y ait un taux de défaillance réduit avec le clou centromédullaire dans les fractures trochanterienne instables.
We report on the optical absorption spectra of gold atoms and dimers deposited on amorphous silica in size-selected fashion. Experimental spectra were obtained by cavity ringdown spectroscopy. Issues on soft-landing, fragmentation, and thermal diffusion are discussed on the basis of the experimental results. In parallel, cluster and periodic supercell density functional theory (DFT) calculations were performed to model atoms and dimers trapped on various defect sites of amorphous silica. Optically allowed electronic transitions were calculated, and comparisons with the experimental spectra show that silicon dangling bonds [[triple bond]Si(.-)], nonbridging oxygen [[triple bond]Si-O(.-)], and the silanolate group [[triple bond]Si-O(-)] act as trapping centers for the gold particles. The results are not only important for understanding the chemical bonding of atoms and clusters on oxide surfaces, but they will also be of fundamental interest for photochemical studies of size-selected clusters on surfaces.
Honey appears to be more effective than sugar in reducing bacterial contamination and promoting wound healing, and slightly less painful than sugar during dressing changes and motion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.