Abnormal motion of the interventricular septum has been described as an echocardiographic feature of both right ventricular volume and pressure overload. To determine if two-dimensional echocardiography can separate these two entities and distinguish them from normal, geometry and motion of the interventricular septum in short-axis views of the left ventricle were evaluated in 12 normal subjects and 35 patients undergoing cardiac catheterization. Thirteen of the 35 patients had uncomplicated atrial septal defect with associated right ventricular volume overload, but no elevation in pulmonary artery pressure. The 22 remaining patients had a pulmonary artery systolic pressure greater than 40 mm Hg and, thus, constituted the group with right ventricular pressure overload. An eccentricity index, defined as the ratio of the length of two perpendicular minor-axis diameters, one of which bisected and was perpendicular to the interventricular septum, was obtained at end-systole and end-diastole. In all normal subjects, the eccentricity index at both end-systole and end-diastole was essentially 1.0, as would be expected if the left ventricular cavity was circular in the short-axis view. In patients with right ventricular volume overload, the eccentricity index was approximately 1.0 at end-systole, but was significantly increased at end-diastole (mean eccentricity index = 1.26 +/- 0.12) (p less than 0.001). In patients with right ventricular pressure overload, the eccentricity index was significantly greater than 1.0 at both end-systole and end-diastole (1.44 +/- 0.16 and 1.26 +/- 0.11, respectively) (p less than 0.001). These results suggest that an index of eccentric left ventricular shape which reflects abnormal motion of the interventricular septum can be defined.(ABSTRACT TRUNCATED AT 250 WORDS)
Echocardiography combined with dobutamine infusion is a safe and accurate method for detecting coronary artery disease and for predicting the extent of disease in those who have localized rest wall motion abnormalities.
Dobutamine stress echocardiography was safely performed using supplemental atropine and an aggressive dosing protocol. Noncardiac side effects were usually minor. Arrhythmias were well tolerated and rarely required treatment. In this study, serious complications from myocardial ischemia did not occur. Symptomatic ischemia was effectively treated with test termination, sublingual nitroglycerin, or short-acting beta-blockers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.