The ejector pump has two main components, namely the electro-motor part and the mechanical part. The electro motor plays a vital role in the activity of draining sea water to the fresh water generator. The electro motor acts as a rotary driver in pump mechanics which has the working principle of converting electrical energy into mechanical energy. Control system and electro protection. The purpose of this research is to determine the cause of overload on a mechanical motor pump. The research was conducted by observation, namely direct observation of the pump which functions as an auxiliary machine. The results show that because the bearings experience excessive heat due to the connection at the center of the motor with the pump not being centered. Gland packing experiencing high speed events so that the shaft is difficult to rotate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.