This paper defines a simple protocol for competitive and quantified evaluation of electromagnetic tracking systems such as the NDI Aurora (A) and Ascension microBIRD with dipole transmitter (B). It establishes new methods and a new phantom design which assesses the reproducibility and allows comparability with different tracking systems in a consistent environment. A machined base plate was designed and manufactured in which a 50 mm grid of holes was precisely drilled for position measurements. In the center a circle of 32 equispaced holes enables the accurate measurement of rotation. The sensors can be clamped in a small mount which fits into pairs of grid holes on the base plate. Relative positional/orientational errors are found by subtracting the known distances/ rotations between the machined locations from the differences of the mean observed positions/ rotation. To measure the influence of metallic objects we inserted rods made of steel (SST 303, SST 416), aluminum, and bronze into the sensitive volume between sensor and emitter. We calculated the fiducial registration error and fiducial location error with a standard stylus calibration for both tracking systems and assessed two different methods of stylus calibration. The positional jitter amounted to 0.14 mm(A) and 0.08 mm(B). A relative positional error of 0.96 mm +/- 0.68 mm, range -0.06 mm; 2.23 mm(A) and 1.14 mm +/- 0.78 mm, range -3.72 mm; 1.57 mm(B) for a given distance of 50 mm was found. The relative rotation error was found to be 0.51 degrees (A)/0.04 degrees (B). The most relevant distortion caused by metallic objects results from SST 416. The maximum error 4.2 mm(A)/ > or = 100 mm(B) occurs when the rod is close to the sensor(20 mm). While (B) is more sensitive with respect to metallic objects, (A) is less accurate concerning orientation measurements. (B) showed a systematic error when distances are calculated.
The overall accuracy of a novel surgical computer-aided navigation system for placement of endosseous implants was evaluated. Five dry cadaver mandibles were scanned using high resolution computed tomography (HRCT). The position of four interforaminal dental implants was planned on the computer screen and transferred to the cadaver mandibles using VISIT, a surgical navigation software developed at the Vienna General Hospital. The specimens were HRCT-scanned again to compare the position of the implants with the preoperative plan on reformatted slices after matching of the pre- and postoperative data sets using the mutual information technique. The overall accuracy was 0.96 +/- 0.72 mm (range 0.0-3.5 mm). No perforation of the mandibular cortex or damage to the mandibular canal occurred. We conclude that computer-aided implant surgery can reach a level of accuracy where further clinical developments are feasible.
Correlation exists between BMD measured with dental quantitative CT and the insertion torque of dental implants.
SUMMARY Gastrointestinal motor function in patients with primary anorexia nervosa has rarely been investigated. We studied oesophageal motor activity in 30 consecutive patients meeting standard diagnostic criteria for primary anorexia nervosa (Feighner et al; DSM III). Seven were found to suffer from achalasia instead of primary anorexia nervosa, one from diffuse oesophageal spasm and one from severe gastro-oesophageal reflux and upper oesophageal sphincter hypertonicity, while partly non-propulsive and repetitive high amplitude, long duration contractions prevailed in the lower oesophagus of another six. In four patients with oesophageal dysmotility not responding to therapy and in 12 of 15 patients with normal oesophageal manometry, gastric emptying of a semisolid meal was studied. Emptying was normal in only three but markedly delayed in 13 cases (half emptying times 97-330 min, median: 147 min, as compared with 21-119 min, median: 47 min, in 24 healthy controls). In eight patients, the effects of domperidone 10 mg iv and placebo were compared under random double blind conditions. Half emptying times were shortened significantly (p<0.01) by domperidone. Conclusions: (1) symptoms of disordered upper gastrointestinal motor activity may be mistaken as indicating primary anorexia nervosa; (2) clinical evaluation of patients with presumed primary anorexia nervosa should rule out the possibility that disordered oesophageal motor activity underlies the symptoms; (3) delayed gastric emptying is a frequent feature in primary anorexia nervosa and might be returned to normal with domperidone.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.