Background: recent short-term observations have shown an improvement in cardiac function and heart failure symptoms from atrio-biventricular pacing. This study was designed to assess the safety and feasibility of an atrio-biventricular transvenous pacing system, and examine the long-term effects of cardiac resynchronization in patients with advanced heart failure and ventricular conduction abnormalities. Methods and results: between August, 1997 and November, 1998, 103 patients received a cardiac resynchronization system (CRS) consisting of a pulse generator interfaced with an atrio-biventricular lead system, including a lead designed for left ventricular (LV) pacing via cardiac veins. Baseline evaluation included 12-lead electrocardiogram, estimation of New York Heart Association (NYHA) functional class, assessment of quality of life (QOL), and distance covered during a 6-min walk (6-MW). Detailed echocardiographic data were also collected in a subset of 46 patients. Measurements were repeated in all surviving patients at 1, 3, 6 and 12 months after implantation of the CRS. A single, self-limiting procedure-related complication occurred. Over a follow-up of 12 months, 21 patients died. The 12-month actuarial survival was 78% (CI 70-87%). Nine surviving patients were withdrawn from the study during long-term follow-up for miscellaneous reasons. At each point of follow-up, a significant shortening of QRS duration was measured. In addition, significant improvements were observed in mean NYHA functional class, 6-MW and QOL score. In the 46 patients with complete echocardiographic data, LV ejection fraction increased from 21.7"6.4% at baseline to 26.1"9.0% at last follow-up (Ps0.006), LV end diastolic dimension decreased from 72.7"9.2 to 71.6"9.1 mm (Ps0.233), interventricular mechanical delay decreased from 27.5"32.1 to 20.3"25.5 ms (Ps 0.243), mitral regurgitation apical four-chamber area decreased from 7. 66"5.5 to 6.69"5.9 cm (Ps0.197), and left ventricular 2 filling time increased from 363"127 to 408"111 ms (Ps0.002). Conclusions: long-term cardiac resynchronization can be safely and reliably achieved by transvenous atrial synchronized right and left ventricular pacing. These changes were accompanied by clinically relevant improvements in functional status and QOL, as well as a measurable increase in LV performance. The outcome of randomised controlled trials is awaited. ᮊ
Brugada syndrome is an inherited cardiac disease and is associated with a peculiar pattern on the electrocardiogram and an increased risk of sudden death. Electrical storm is a malignant but rare phenomenon in symptomatic patients with Brugada syndrome. We describe a patient who presented with repetitive ICD discharges during two episodes of recurrent VF. After the initiation of isoproterenol infusion and oral quinidine, the ventricular tachyarrhythmias were successfully suppressed. (Neth Heart J 2007;15:151-4.).
LV reverse remodeling and beneficial echocardiographic changes were sustained during 2 years follow-up. A 5% or more increase in LVEF after 3 months was associated with a better long-term survival.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.