When activated the platelets release growth factors that play an essential role in bone healing such as Plateletderived Growth Factor, Transforming Growth Factor-β, Vascular Endothelial Growth Factor and others. Several techniques for platelet concentrates such Platelet Rich Plasma (PRP) and Platelet Rich Fibrin (PRF) have been introduced in surgical field for the prevention of hemorrhage and acceleration of tissue regeneration. Recently, a novel technique of fabricating growth factors-enriched bone graft matrix have been proposed termed as "sticky bone" or "mineralized plasmatic matrix", which contains platelets and fibrin concentrate in a liquid state; these materials can become bound to bone particles. The filling material is easy to shape and a PRF-type membrane is also generated. In our case report, mineralized platelet matrix have been used after the extraction of a fractured single rooted tooth in order to preserve the dimensions of the post-extractive socket, facilitate new bone formation and to reduce healing time.
Traumatic dental injuries in permanent teeth, especially the maxillar incisors, are very common. The ultimate goal of any dental emergency treatment is to re-establish normal tooth position together with normal function. Numerous techniques to restore fractured crowns can be used. The reattachment of fractured fragment is an option that can provide immediate esthetic, functional and biologic restoration.
Objectif : L'aspect du tissu gingival joue un rôle important dans l'esthétique de la région maxillaire antérieure. Le zénith gingival (GZ) est défini comme le point le plus apical de la collerette gingivale marginale ; pourtant, sa situation mésio-distale (MD) n'est pas bien déterminée. Ainsi, cette étude vise à quantifier le déplacement spatial spécifique du GZ dans la dentition maxillaire antérieure. Méthodes :Le déplacement mésio-distal du zénith gingival par rapport au grand axe des couronnes, a été mesuré avec un pied à coulisse numérique sur des modèles en plâtre issus de moulage d'empreinte des dents antérieures pris sur des sujets volontaires en bonne santé parodontale, qui ont été enregistrés au 1/100 e mm sur la canine (C), l'incisive latérale (LI) et l'incisive centrale (CI).Les différences entre les mesures ont été analysées avec test-t pour les variables continues et x²-test pour les pourcentages. Une valeur α = 0,05 a été utilisée pour déclarer la signification statistique.Résultats : Cette étude a démontré que le zénith gingival était déplacé en situation distale par rapport au grand axe au niveau des incisives centrales, avec une moyenne de 1,02 mm, de même pour les incisives latérales avec une moyenne de 0,42 mm ; au niveau des canines, avec une moyenne de 0,11 mm.Le GZ était déplacé distalement dans 100 %, 88 % et 51 % des incisives centrales, incisives latérales et canines, respectivement. Conclusion :Le GZ n'est pas universellement déplacé en distal. La fréquence et l'étendue du déplacement distal sont dépendantes de la dent. Il est plus grand pour CI que pour LI, qui, à son tour, est plus grand que pour C. La prise en considération de ces conclusions peut améliorer l'approche clinique du complexe dento-gingival et améliorer de même la gestion dento-parodontale des procé- Cette étude vise à une évaluation quantitative du déplacement spatial du zénith gingival dans la dentition maxillaire antérieure en mesurant la distance mésio-distale du zénith gingival par rapport au grand axe des couronnes dentaires (incisive centrale, incisive latérale, canine). 98Actualités Odonto-Stomatologiques -n° 258 -juin 2012
A large number of all-ceramic materials represent today, an alternative to metal-ceramic. However, it must be noted that despite these advances, the exact reproduction of natural teeth remains a challenge for both the practitioner and the laboratory technician. Reproducing the optical properties of natural teeth is not always easy. The "right" choice of ceramic reconstruction material for an anterior single crown is the basis of successful reconstruction (Figure 1a, 1b). Nowadays, there is no universal material or system that can be used in all clinical situations. The choice has become difficult because of the large number of existing processes. It is resulting of experience more often, rather than rigorous rational reflexion.
A highly accurate impression is one of success requirements in implant dentistry. A passively fitting prothesis is achieved when the 3-dimensional position of the implants is precisely transferred to the cast. Various impression techniques are described in the literature. Each one presents indications, qualities and limits. Many studies compared the main techniques which are closed and open-tray impressions along with their specificities. In this second part, the open-tray technique is described and discussed then compared with the closed-tray one.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.