Colorectal adenoma is linked to metabolic dysfunction. Metabolic dysfunction-associated fatty liver disease (MAFLD) has a precise definition and three subtypes, including non-obese MAFLD. We aimed to investigate the impact of MAFLD on the prevalence of colorectal adenoma by comparing it to non-alcoholic fatty liver disease (NAFLD) in health check-up examinees. This is a multicenter retrospective study. We enrolled 124 consecutive health check-up examinees who underwent colonoscopy. NAFLD and MAFLD were present in 58 and 63 examinees, respectively. Colorectal adenoma was diagnosed by biopsy. The impact of the MAFLD definition on the prevalence of colorectal adenoma was investigated by logistic regression, decision-tree, and random forest analyses. In logistic regression analysis, MAFLD was identified as the only independent factor associated with the presence of colorectal adenoma (OR 3.191; 95% CI 1.494–7.070; p = 0.003). MAFLD was also identified as the most important classifier for the presence of colorectal adenoma in decision-tree and random forest analyses (29 variable importance value). Among the three subtypes of MAFLD, non-obese MAFLD was the sole independent factor associated with the presence of colorectal adenoma (OR 3.351; 95% CI 1.589–7.262; p ≤ 0.001). Non-obese MAFLD was also the most important classifier for the presence of colorectal adenoma in decision-tree and random forest analyses (31 variable importance value). MAFLD, particularly non-obese MAFLD, is the most important factor associated with the presence of colorectal adenoma rather than NAFLD. Colonoscopy examination should be considered in patients with MAFLD, especially those who are non-obese.
The purposes of this study were to evaluate the image quality of five types of liquid-crystal display (LCD) monitors by utilizing the normalized-rank approach and to investigate the effect of LCD monitor specifications, such as display colors, luminance, and resolution, on the evaluators' ranking. The LCD monitors used in this study were 2, 3 and 5 mega-pixel monochrome LCD monitors, and 2 and 3 mega-pixel color LCD monitors (Eizo Nanao Corporation). All LCD monitors were calibrated to the grayscale standard display function (GSDF) with different maximum luminance (recommended luminance) settings. Also, four kinds of radiographs were used for observer study based on the normalized-rank approach: three adult chest radiographs, three pediatric chest radiographs, three ankle joint radiographs, and four double-contrasted upper gastrointestinal radiographs. Ten radiological technologists participated in the observer study. Monochrome LCD monitors exhibited superior ranking with statistically significant differences (p<0.05) compared to color LCD monitors in all kinds of radiographs. The major difference between monochrome and color monitors was luminance. Therefore, it is considered that the luminance of LCD monitors affects observers' evaluations based on image quality. Moreover, in the case of radiographs that include high frequency image components, the monitor resolution also affects the evaluation. In clinical practice, it is necessary to optimize the luminance and choose appropriate LCD monitors for diagnostic images.
SummaryWe evaluated the effect of orthopedic-metal artifact reduction (O-MAR) for metal artifact in computed tomography with 73 simulated seeds for brachytherapy in different sizes of display field of view (DFOV) obtained by helical scan under the same clinical scan condition. The metal artifacts were analyzed with the Gumbel's method by changing DFOV sizes 80 mm, 160 mm, and 320 mm. Gumbel distribution, scale parameter (γ), and location parameter (β) of the metal artifacts with O-MAR were compared with that of the metal artifacts with filtered back projection (FBP). In conclusion, it was considered that the effect of metal artifact reduction with O-MAR was influenced by DFOV size in this study. The reduction rates of scale parameter (γ) were 22.3%, 21.3%, and 10.0% in DFOV 80 mm, 160 mm, and 320 mm, respectively. The reduction rates of location parameter (β) were 27.4%, 23.4 %, and 9.8%. Therefore, the effect of metal artifact reduction with O-MAR showed the tendency of increasing with decreasing DFOV size.
The purpose of this study was to examine the correlation between the basic imaging properties of two digital radiographic X-ray systems with a direct conversion flat-panel detector and their image qualities, which were evaluated by the observer in hard copy and soft copy studies. The subjective image quality was evaluated and compared in terms of the low-contrast detectability and image sharpness in the two digital radiographic X-ray systems. We applied the radiographs of a contrast detail phantom to the evaluation of low-contrast detectability and analyzed the contrast detail diagrams. Finally, low-contrast detectability was evaluated by the image quality figure (IQF) calculated from the contrast detail diagrams. Also, the subjective image sharpness of human dry bones of two systems was examined and evaluated by the normalized-rank method. The results indicated that System A tended to provide superior subjective image quality compared to System B in both observer studies. We also found high correlations between IQFs and basic imaging properties, such as the noise power spectrum (NPS) and the noise equivalent quantum (NEQ). In conclusion, the low-contrast detectability of the two digital radiographic X-ray systems with a direct conversion flat-panel detector corresponded to the NPS and the NEQ in both outputs (soft copy and hard copy). On the other hand, the subjective image sharpness of human dry bones was affected by their noise properties.
It has been difficult to obtain accurate radiographlc images of the oblique cervical spine in the supine posi − tion . We developed a new technique that combined the sliding top bucky table and a radiographic supporting device. Our technique improved the reproducibility of images because the geometry was a ] ways the same , Fur − ther , no special technique is required . The radiographic mag 丗 且cation factor of the supine position wa . s approxi − mately l3 % larger thamhat of the standing position , but image quality − amd clinical evaluation were a ユ most the same . In conclusion , our new technique for oblique pr 〔} jection of cervical spine radiography in the supine posi − tion does not require co − workers to hold the patient In addition , thistechnique provjded cervical spine radiog − raphy with reduced discomfbrt for the patient , 闢 ・
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.