Background-We used intravascular ultrasound (IVUS) to evaluate recurrence after sirolimus-eluting stent (SES) implantation treatment of in-stent restenosis (ISR). Methods and Results-Forty-eight ISR lesions (41 patients with objective evidence of ischemia) were treated with SES.Recurrent ISR was identified in 11 lesions (all focal); repeat revascularization was performed in 10.
In the majority of bifurcation lesions treated with the crush technique, the smallest minimum stent area appeared at the SB ostium. This may contribute to a higher restenosis rate at this location.
Background-Little is known about causes of intimal hyperplasia (IH) after sirolimus-eluting stent (SES) implantation.Methods and Results-Intravascular ultrasound was performed in 24 lesions with intra-SES restenosis and a comparison group of 25 nonrestenotic SESs. To assess stent strut distribution, the maximum interstrut angle was measured with a protractor centered on the stent, and the visible struts were counted and normalized for the number of stent cells. In SES restenosis patients, minimum lumen site was compared with image slices 2.5, 5.0, 7.5, and 10.0 mm proximal and distal to this site. The minimum lumen site had a smaller IVUS lumen area at follow-up (2.7Ϯ0.9 versus 6.2Ϯ1.9 mm 2 ; PϽ0.01), larger maximum interstrut angle (135Ϯ39°versus 72Ϯ23°; PϽ0.01), larger IH area (3.4Ϯ1.5 versus 0.6Ϯ1.1 mm 2 ; PϽ0.01) and thickness (0.7Ϯ0.3 versus 0.1Ϯ0.2 mm; PϽ0.01) at maximum interstrut angle, and fewer stent struts (4.9Ϯ1.0 versus 6.0Ϯ0.5; PϽ0.01) even when normalized for the number of stent cells (0.78Ϯ0.15 versus 0.97Ϯ0.07; PϽ0.01). Compared with nonrestenotic SES, the restenosis lesions also had a smaller minimal lumen area, larger IH area, thicker IH at maximum interstrut angle, fewer stent struts, and larger maximum interstrut angle. Multivariate analysis identified the number of visualized stent struts normalized for the number of stent cells and maximum interstrut angle as the only independent IVUS predictor of IH cross-sectional area (PϽ0.01 and PϽ0.01), minimum lumen area (PϽ0.01 and PϽ0.01), and IH thickness (PϽ0.01 and PϽ0.01). Conclusions-The number and distribution of stent struts affect the amount of neointima after SES implantation.
In tandem and diffuse coronary disease, iFR pullback predicted the physiological outcome of PCI with a high degree of accuracy. Compared with angiography alone, availability of iFR pullback altered revascularization procedural planning in nearly one-third of patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.