Accidental injury with scissors led to an open globe injury with iris prolapse and corneal tissue loss in the right eye of a 15-year-old girl. Attempts to suture the laceration normally, led to persistent aqueous leak, and tight suturing was leading to unacceptable distortion of the corneal contour. In the absence of donor tissue or tissue glue, a bulbar conjunctival pedicle flap was used to augment sutures placed without undue tension, and watertight closure of the globe was achieved. Postoperatively, the flap retracted, and excellent tectonic, cosmetic and refractive outcomes were achieved. A conjunctival pedicle flap can be a useful adjunct in the armamentarium of the corneal surgeon while dealing with open globe injuries with corneal tissue loss.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.