A method was developed for the rapid and quantitative analysis of 30 veterinary drugs belonging to 17 classes (amphenicols (1), anthelmintics (1), cephalosporins (4), coccidiostats (1), lincosamides (1), macrolide (1), nitroimidazole (1), penicillins (3), phenylhydrazines (1), polypeptides (1), pyrethrins (1), quinolones (5), sulfonamides (3), tetracycline (3), neuroleptic agents (1), triazene trypanocidal agents (1), other. (1)) in feeds. The proposed method with a modified Quick Polar Pesticides (QuPPe) sample preparation was validated for the determination of 30 veterinary drugs in feed samples by liquid chromatography triple-quadrupole mass spectrometry (LC–MS/MS). The sample was extracted with methanol containing 1% acetic acid and purified by dispersive solid-phase extraction (d-SPE) with C18. Good linearity (r2 ≥ 0.98) was observed, and the LOQ values ranged from 10 to 200 µg/kg. Average recoveries ranged from 70.8 to 118.4%, and the relative standard deviation was ≤ 18.7%. This validated method was used in the determination of 30 veterinary drugs in 142 feed samples obtained from South Korea. The results show that lincomycin was present in only one of the tested feed samples, although it was detected at a value lower than the LOQ. In conclusion, this multi-residue method can be used for screening through the detection and quantitation of residual multiclass veterinary drugs in feed samples.
Background: To suggest a reasonable isometric point based on the anatomical consistency of interosseous membrane (IOM) attachment in association with topographic characteristics of the interosseous crest, the footprints of the central band (CB) of the IOM on the radial and ulnar interosseous crests (RIC and UIC) were measured.Methods: We measured the distance from the CB footprints from each apex of both interosseous crests in 14 cadavers and the angles between the forearm axis of rotation (AOR) and the distal slopes of the RIC and UIC in 33 volunteers. Results: The CB footprints lay on the downslope of both interosseous crests with its upper margin on average 3-mm proximal from the RIC's apex consistently in the radial length, showing normality (p>0.05), and on average 16-mm distal from the UIC's apex on the ulna without satisfying normality (p<0.05). The average angle between the UIC's distal slope and the AOR was 1.3°, and the RIC's distal slope to the AOR was 14.0°, satisfying the normality tests (p>0.05), and there was no side-to-side difference in both forearms (p<0.05).Conclusions: The CB attached to the downslope just distal to the RIC's apex constrains the radius to the UIC that coincides with the AOR of the forearm circumduction, maintaining itself both isometrically and isotonically.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.