A directly rapid quantification method for chemical oxygen demand (COD) of wastewater was established by Fourier transform infrared (FTIR) spectroscopy combined with attenuated total reflection (ATR) technology and moving window partial least squares (MWPLS) method with changeable parameters. All samples were firstly divided into the calibration set and the prediction set. And then according to the predicion effect, the optimal model was selected, and the corresponding waveband, number of adopted wavenumbers, PLS factor, root mean squared error of predication (RMSEP), correlation coefficient of predication (RP) were 3152-1109 cm-1, 1060, 8, 21.5 mg/L, and 0.981 respectively, which was obviously superior to the optimal PLS model on the whole spectral collecting region. The result shows that FTIR/ATR spectroscopy can be applied to the rapid determination of COD of wastewater, and the waveband selected by MWPLS method with changeable parameters has higher signal to noise ratio, which can effectively improve the precision of the predictive model.
The rapid quantification method of glucose aqueous solution was established by using the Fourier transform infrared spectroscopy (FTIR) and attenuated total reflection (ATR). Model optimization and wavenumbers selection was investigated based on Savitzky-Golay (SG) smoothing. For the whole spectral collecting region 4500-600 cm-1 and the fingerprint region 1600-900 cm-1, Partial least squares (PLS) models without and with SG smoothing were established respectively. The optimal model was on the fingerprint region with SG smoothing of 1st order derivative, 2nd degree polynomial and 73 smoothing points, PLS factor, RMSEP, RP, were 4, 0.331 mmol/L, 0.999 respectively. Based on 19 absorption peaks of the subtracted spectra of glucose aqueous solution for de-ionized water, all possible wavenumber combinations were used to establish discrete multiple linear regression (MLR) models respectively, the optimal wavenumbers combination was 3084, 1034, 991 (cm-1), RMSEP and RP were 0.459 mmol/L, 0.997 respectively. It could provide valuable references for designing spectrophotometer system in special spectrometer and further for glucose analysis of the complex system. To get the stable prediction results, all models and results here were obtained based on the average data on 50 different divisions of calibration set and prediction set.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.