Two approaches of an automatic control were studied through mathematical fitting obtained from color mixing saturation curves in polydimethylsiloxane microfluidic devices: The integrative control with variable integral gain and integrative control with constant integral gain. The aim of this work is to control the color percentage decrement when dye is injected. The results indicate that microfluidic systems are very sensitive to changes in flow and the control variable needs to change slowly; that is, it must be small (at least 100 times less than the theoretically calculated values). The control and stabilization of the microfluidic system were achieved for dye percentages above 60%. The controlling color percentage could provide a tool to regulate other parameters’ concentration applied to cell culture and alkalinity control (pH) of solutions in microfluidic devices.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.