The effectiveness of heat transfer and the pressure drop coefficient of staggered elliptical tube banks are studied experimentally. The bank consists of 11 elliptical tubes of 0.75 equivalent diameter in an arrangement of 4-3-4. The major and the minor sub-axis of each tube are 24.70 mm and 12.35 mm respectively, and therefore the aspect ratio (AR) of the tube is 2.0. The geometric parameters of the bank are ST = 24.70 mm, SL = 37.00 mm and minimum frontal area B = 12.35 mm. Seven mid-tubes are internally heated by electrical heater of 69.6 Watt each. Experiment is conducted in a sub sonic wind tunnel and run with the wind velocities of 1 m/s 12.6 m/s which correspond with Reynolds number of = 346-6904. The results show that the effectiveness (ε) varied from 2144.44 to 15.26. It decreases exponentially at low Reynolds numbers and tended asymptotically at higher Reynolds number. The coefficient of pressure drop (CΔp) ranges from 7.21 to 4.41 decreases continuously at low Reynolds number and asymptotic at higher one.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.