A control strategy with distributed corrective action for distillation has been proposed and consists of a conventional dual temperature control combined with an additional column tray. In this work, we evaluated the influence of the location of this internal loop as part of the new proposal, compared to a conventional system. Tests were carried out in a 13-column tray distillation equipment and feed temperature was disturbed. Two different column trays from the stripping section were used (11 and 12) for internal decentralized temperature control, each one separately, plus the dual control of top and bottom temperatures. The results demonstrated that this proposed control approach with distributed corrective action is faster than the conventional one, regardless of the column tray in use. It was also determined that the internal loop close to the feed (disturbance) is more interesting as a way to minimize transients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations –citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.