Since the turn of the century, robotic-assisted colorectal surgery has been synonymous with the da Vinci ® robotic surgical system. We report in this study our first results in robotic-assisted sigmoid resection for diverticular disease using the Senhance™ Surgical Robotic System, while introducing a standardized roadmap for engaging the robotic arms. 12 patients underwent a sigmoid resection using the Senhance™ Surgical Robotic System. All four arms of the robotic system were engaged during all procedures according to a previously devised roadmap. A 4-trocar technique was used in all patients. Perioperative data, including those regarding technical difficulties, were collected and analyzed. Two procedures were converted into standard laparoscopy. There were no conversions to open surgery. The mean age of the patients was 62.5 years (47-79). One third of the patients were males. The mean BMI was 27 kg/m 2 (19-38). The mean operative time, the mean console time and the mean docking time were 219 min (204-305), 149 min (124-205) and 10 min (6-15), respectively. The mean length of stay was 9 days (6-15). There was one major complication (8.3%, Clavien-Dindo IIIb). There were no mortalities. No other complications were observed. No patients were readmitted after discharge. The Senhance™ Surgical Robotic System can be used safely in sigmoid resection for diverticular disease after adequate training and systematic planning of the different steps of the procedure. Further experience is needed to judge the benefit for patient and surgeon, as well as the cost and time effectiveness.
Introduction: Robotic surgery was first introduced in the mid-1980s, and at the end of the '90s, the da Vinci® System (Intuitive Surgical Inc., Sunnyvale, California) was introduced in Europe and held a monopoly for years afterward. In 2016, Senhance™ digital laparoscopic platform (Asensus Surgical, Durham, North Carolina) came to the market. This new platform is based on laparoscopic movements and is designed for laparoscopic surgeons. This study shows the surgical outcomes of patients after different visceral, colorectal, gynecological, and urological surgical procedures done with the Senhance™ digital laparoscopic platform with a focus on safety. Materials and Methods: The study population consists of 871 patients who underwent robotic surgery with the Senhance™ platform. The most common procedures were hernia repairs (unilateral and bilateral), cholecystectomies, and prostatectomies. The procedures were performed in five centers in Europe between February 2017 and July 2020 by experienced laparoscopic surgeons. Results: 220 (25.3 %) out of 871 patients had a unilateral hernia repair, 70 (8.0%) a bilateral hernia repair, 159 (18.3%) underwent a cholecystectomy, and 168 (19.3%) a prostatectomy. The other procedures included visceral, colorectal, and gynecological surgery procedures. The median docking time was 7.46 minutes for the four most common procedures. The duration of surgery varied from 32 to 313 minutes, the average time was 114.31 minutes. Adverse events were rare overall. There were 48 (5.5 %) adverse events out of 871 patients, 24 of them (2.8 % of all cases) were severe. Out of all 24 severe adverse events, five events (20.8%) were likely related to the robot, 17 events (70.8%) were unlikely related to the robot, and two events (8.3%) could not be categorized. Regarding complications following unilateral hernia repairs, data from 212 patients was available. Thirteen (6.1%) complications occurred, and six of those (2.8%) were serious. Out of 68 patients with a bilateral hernia repair, six patients (8.8%) developed complications, three of which were severe (4.4%). The complication rate was 2.8% in the patients following a cholecystectomy (4/144); two of them serious. After prostatectomy, six out of 141 patients (4.3 %) had complications; one serious (0.7%) No mortality was observed. Data about unplanned conversions to laparoscopic surgery could be collected from 761 patients which is a rate of 3.7%. There were 12 conversions out of 760 procedures to open surgery (1.6%). Conclusions: Our series shows these procedures are safe and reproducible. The findings suggest that the surgical results after robotic surgery with the Senhance™ system are promising. Long-term data regarding complication rates should be the subject of future studies.
Purpose: The advent of robotic surgery has highlighted the advantages of articulation. This dry-lab study examined the dexterity and learning effect of a new articulated laparoscopic instrument: the ArtiSential® forceps (LIVSMED, Seongnam, Republic of Korea). Methods: A peg board task was designed. Three groups of volunteers with varying levels of laparoscopic expertise were organized to perform the task: expert, intermediate and novice. The participants performed the task using articulated and straight instruments, once before a 30-min training session and once afterwards. The times required to perform the task were recorded. The performances were analyzed and compared between the groups as well as between the straight and articulated instruments. Results: The experts were significantly faster than the novices with both instruments before the 30-min training session (p = 0.0317 for each instrument). No significant time difference was found among the three groups after the 30-min training session. The decrease in the time required to perform the peg-transfer task with the articulated instrument was significantly greater in the novice and intermediate groups (p = 0.0159 for each group). No significant difference in time reduction was observed between the groups with the straight instrument. Regardless of the user, the articulated device was associated with faster task performance than the straight device after 8 hours of training (p = 0.0039). Conclusion: The ArtiSential® articulated device can improve dexterity. A significantly greater learning effect was observed in the novice and intermediate groups in comparison with experts. A plateau in the learning curve was observed after a few hours of training.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.