MRI is of only limited diagnostic performance, while BIPSS is the most accurate way to establish the diagnosis of CD. The routine use of a multimodality diagnostic approach including BIPSS, MRI, and biochemical tests is suggested to avoid the risk of mismanagement for patients with CS.
The small number of complications observed during acts of interventional uroradiology prove transcutaneous manipulations to be safe medical procedures.
Context:Although bilateral inferior petrosal sinus sampling (BI-PSS) with CRH stimulation is the most accurate procedure for the differential diagnosis of ACTH-dependent Cushing's syndrome (CS), 4 -15% of patients with Cushing's disease (CD) fail to demonstrate diagnostic gradients. Preliminary data suggest that a more potent stimulation by the combined administration of CRH plus desmopressin during BIPSS may provide some diagnostic advantage. A crucial issue, however, is whether such an amplified stimulation may affect the specificity of the procedure, and this was the main aim of the present study.
Objective:We investigated the diagnostic accuracy of BIPSS performed by CRH plus desmopressin stimulation.
Design and Setting:A retrospective analysis was conducted at a single tertiary care center.
Participants:Fifty-four patients were admitted for the investigation of ACTH-dependent CS. CD was diagnosed in 47 patients; occult ectopic ACTH syndrome (oEAS) was histologically confirmed in seven patients.
Intervention(s):All patients underwent BIPSS with CRH plus desmopressin administration. Additional noninvasive tests included CRH test, high-dose dexamethasone suppression test, desmopressin test, and pituitary magnetic resonance imaging.
Main Outcome Measures:Gradients of inferior petrosal sinus (IPS) to peripheral (IPS/P) ACTH were calculated before and after stimulation with CRH plus desmopressin.
Results:The sensitivity for a basal IPS/P gradient greater than 2 was 61.7%, with 100% specificity and a diagnostic accuracy of 66.7%. After stimulation with CRH plus desmopressin, receiver operating characteristic (ROC) curve analysis showed that a cutoff gradient of more than 2 offers the best test performance. In total, 46 of 47 patients with CD had an IPS/P gradient greater than 2, but none of the patients with oEAS, resulting in a sensitivity of 97.9%. The specificity was 100%, diagnostic accuracy was 98.2%, and the positive and negative predictive values were 100 and 87.5%, respectively. A subgroup of 18 patients (16 with CD and two with oEAS) had contradictory responses to routine tests with CRH and/or high-dose dexamethasone suppression test; sensitivity, specificity, and accuracy of BIPSS in this subgroup were 100%.
Conclusions:The application of a combined stimulation with CRH plus desmopressin during BIPSS is associated with a high sensitivity but no loss of specificity. (J Clin Endocrinol Metab
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.