BackgroundTo assess the constants and formula for aphakia correction with iris-claw IOLs to achieve the best refractive status in cases of late in-the-bag IOL complex dislocation.MethodsA literature search was performed. The following data were obtained: Iris-claw IOL model, Iridal or retroiridal enclavation, A-constant, ultrasound or optical biometry, formula employed and refractive outcomes. Acceptable emmetropia was considered if the resulting spherical equivalent (SE) was within ±1.00 D.ResultsThe majority of the studies used SRK/T formula (66.6%). The 88.9% of the reports obtained a SE within ±1.00 D. Using A-115 for ultrasound biometry and A-115.7 for optical biometry and SRK/T formula, the emmetropia (±1.00 D) of SE, was able to get near 100% of reported cases over the pupil implantation. However, the emmetropia decreased to 80% when the enclavation is retropupilar using the same formula. The A-constant can vary from 116.7 to 117.5 for retropupilar enclavation.ConclusionsUsing A-115 for ultrasound biometry and A-115.7 for optical biometry and SRK/T formula, ±1.00 D of SE, is able to get near 100% of cases. Nevertheless, ±1.00 D of SE decreased to 80% of the cases when the enclavation is retropupilar.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.