Purpose: To examine the microscopic surface features, chemical composition, and thermodynamic profile of seven endodontic sealers (AH Plus, Adseal, MTA-Fillapex, RoekoSeal, GuttaFlow 2, GuttaFlow BioSeal, and EndoRez) exposed to high-temperature changes using an endodontic obturation device. Methods: The thermal properties were examined using scanning calorimetry (DSC) and thermogravimetric analysis (TGA). Then, six disc-shaped specimens of each sealer were prepared and divided into two groups -a room temperature group and a heat exposure group -for analysis of surface and chemical changes using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). Results: DSC analysis showed that AH Plus had the highest exothermal signal (122.9°C), while TGA analysis showed that MTA-Fillapex was most affected by increased temperature (32.4% mass loss at 230ºC). SEM analysis showed that while AH Plus and GuttaFlow BioSeal maintained their surface integrity after heat exposure, the EDS profiles demonstrated changes in the chemical composition of the sealers after heat exposure for 5 s. High-temperature exposure had a negative impact on the properties of five of the sealers (Adseal, MTA-Fillapex, RoekoSeal, GuttaFlow 2, and EndoRez). Conclusion: AH Plus and GuttaFlow BioSeal showed minimal changes upon high-temperature exposure, suggesting their suitability for thermal endodontic obturation techniques.
Purpose:The aim of this study was to categorize the effects of heat on coronal obturation with gutta-percha and sealer using X-ray micro-computed tomography (micro-CT). Methods: Ten single-rooted, extracted human teeth were shaped using ProTaper NEXT files to size X5 (#50/Taper 6%) with 2.5% NaOCl irrigation. A single ProTaper NEXT X5 gutta-percha point was then inserted with epoxy resin (AH Plus) or tricalcium silicate (EndoSequence BC) sealer (n = 5/group), and cut at the cemento-enamel junction. The teeth were scanned using micro-CT (SkyScan1272) to obtain 11 sagittal 2-D images. Three calibrated raters categorized the coronal 0.5 mm of the images into four categories: "swirled sealer and/or gutta-percha without voids" (I), "uniform voids and sealer/gutta-percha" (II), "non-uniform voids and sealer/gutta-percha" (III), and "swirled sealer and/or guttapercha with voids" (IV). Intra-rater and inter-rater reliability were then calculated. Chi-square tests were conducted to determine the significance of differences in each category between sealers.
Results:The intra-class correlation coefficient was 0.55 (same rater/two different times) and Fleiss' kappa (different raters/same image) was 0.34.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.