We wished to determine which areas of the visual field contribute most strongly and most frequently to the deterioration of the visual fields in patients with high ocular pressure. The computerized analysis, using linear and multiple regressions of the findings in 382 visual fields, allowed us to select four test points sensitive enough to estimate the actual global sensitivity of the central visual field (correlation coefficient, 0.98). This system also allowed us to estimate the number of pathological points and even to classify accurately over 75% of the cases in terms of their normal or pathological condition, as well as to determine the depth of the defect. The remaining cases show that the deterioration, if it exists, is not significant. Requiring less than 1 min a threshold examination at these four test points enables us to acquire greater insight into the glaucomatous defect.
An evaluation was carried out comparing Oculokinetic Perimetry (O.K.P.) with Automatic Perimetry of Thresholds (Hipocampus Perimeter) for ocular hypertension and glaucoma studying 145 eyes. The O.K.P. shows a sensitivity between 35.65 and 38.54%, a specificity of 76.67-79.59%, a + predictive value of 78.72-85.42%, and a-predictive value of 23.71-39.80%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.