Performance of a bolted flange joint is characterized mainly by its 'strength' and 'sealing capability'. Sealing capability of a bolted flange joint is highly dependent on the bolt up strategy during assembly because gasket stress distribution achieved during assembly process is the prime parameter. Any improper bolt up practice may result in the leakage from the joint. In this article, two different bolt up strategies used in the industries during the assembly of a bolted flanged joint are used and joints relaxation, gasket stress variation, and joint's strength are analysed using detailed non-linear finite-element analysis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.