The model-based methods of maximum power point (MPP) tracking in photovoltaic installations are widely known. One of these methods proposes the use of tracking by direct estimation of the maximum power point resistance using irradiance measurement processing. It proposes six different models for this estimate. In the present work, an exhaustive analysis to determine the robustness and accuracy of the different models was carried out. To perform the analysis, irradiance data sets, used to fit the parameters of the models, were collected. In addition, tests were done to determine MPP tracking accuracy of each of the six models. To carry out the tests, all models were compared with a widely used maximum power point tracking algorithm, perturb & observe, for different values of irradiance, temperature, and load.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.