Myocardial ischemia, the condition in which an insufficient supply of oxygen to the heart muscle occurs due to a decrease in coronary blood flow, damages the mechanical function of the LV and may impair pulse transmission. To investigate this, the power associated with the forward (Wf) and reflected (Wr) waves were computed for the normal and ischemia-compromised left ventricle. Results show that power generated by the ischemic heart is decreased as expected, but the pulsatile transmission of pressure and flow is little affected. I "Hydraulic power in the vascular system is made up of a steady, non-pulsatile term and an oscillatory term [ l ] W t = w s + WO (1) with the steady power equal to the product of mean pressure and mean flow, and the oscillatory term defined in terms of the pulsatile flow (Qn) and the input impedance (Zn) harmonics,This concept has been applied to the systemic circulation by many investigators, especially in studying left ventricular energetics in disease states such as congestive heart failure [2] and hypertension [3,4]. By separating pressure and flow waves into their forward and reflected components the pulsatile power can be resolved into its components with respect to wave reflections, i.e the power that could be delivered in a reflectionless system (with the forward wave) and the power dissipated due to the actual state of the arterial system (with the reflected wave). Thus the power associated with a reduced-energy state such as myocardial ischemia and the effect of this decreased power on pulse wave transmission to the arterial system can be more effectively studied. METHoDSAortic flow, pressure and the standard lead I1 ECG were simultaneously measured in anaesthetized dogs. The data were recorded on an FM recorder (Vetter C-4) and on a paper recorder. Steady state recordings were made during control and after approximately one hour of mechanical occlusion of the left anterior descending (LAD) coronary artery Measured pressure and flow were digitized at 10 msec intervals. The characteristic impedance (20) was estimated in the time domain during the first 60 msec of systole as before [3,41where AF' is the instantaneous aortic pressure above end diastole and Q is the instantaneous flow. Compliance (C) and peripheral resistance (Rs) were determined in the time domain as before [4]. Measured pressure (P) and flow (Q) waves were separated into their forward (Pf, Qf) and reflected (Pr, Qr) components. Fourier analysis was performed on all the pressure and flow waveforms. In-phase pulsatile power was defined by Wn = I Pn I I Qn I COS 8 (4)where n represents the harmonic value and 8 the phase angle.Similarly, the power associated with the forward pulse wave can be expressed asand the power dissipated along the transmission path due to reflections can be considered as Wm = I Pm I I Q n I COS (e m + Q fn) (6)Only the power contained in the first three harmonics, which accounts for more than 90% of total power, are presented.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.