RESUMOAmostras de leite foram coletadas de tanques de expansão (n = 69) e das vacas individualmente (n = 3517), em propriedades com sistema de produção especializado (ES, n = 3), semiespecializado (SE, n = 5) e não especializado (NE, n = 7). A composição, contagem de células somáticas (CCS) e teor de nitrogênio ureico (NU) foram avaliados nos diferentes sistemas e estações do ano. Os dados foram comparados aos parâmetros da Instrução Normativa 51/2002 (IN51) para a região Sul do Brasil, de maio/2009 a junho/2010. Analisando os três sistemas de produção, 42% (n = 29/69) das amostras de leite dos tanques de expansão e 11% (n = 375/3517) das individuais atenderam a IN51. Amostras de leite de tanque do sistema ES 70% (n = 14/20), SE 39% (n = 9/23) e NE 23% (n = 6/26) atenderam os critérios da IN51. Amostras de leite individuais apresentaram menor percentual com parâmetros mínimos da IN51 comparada ao tanque. O leite de vacas sadias dilui a CCS de vacas doentes, indicando que a CCS do tanque não é um indicador confiável para qualidade do leite. Os teores médios de gordura, proteína e sólidos totais em amostras de tanque foram semelhantes entre os sistemas de produção. A lactose e NU nas amostras do tanque foram similares entre as estações do ano. Em contraste, a CCS do tanque e individual não alcançaram os parâmetros da IN51. O teor médio de NU foi maior (P < 0,001) nas amostras de leite de tanque e individual do sistema especializado. A análise de amostras de leite de cada vaca permitiu melhoria nutricional do rebanho especializado. PALAVRAS-CHAVE: CCS, tanque de expansão, composição do leite. ABSTRACT MILK QUALITY IN SAMPLES FROM INDIVIDUAL DAIRY COWS AND MILK TANKS.Bovine milk samples were collected from milk tanks (n = 69) and from individual cows (n = 3,517) on specialized (S, n = 3), partially specialized (PS, n = 5) and nonspecialized (NS, n = 7) production systems. Compositions, somatic cell count (SCC) and urea nitrogen content were analyzed for the different production systems and all the four seasons. Data were compared to the ranges allowed by the Federal Normative Instruction 51/2002 (IN51) for South Brazil from May 2009 to June 2010. Forty-two percent (n = 29/69) of all milk samples obtained from tanks and 11% of the individual samples in the three production systems met IN51 standards. Of the collected tank samples, 70% (n = 14/20), 39% (n = 9/23) and 23% (n = 6/26) of the S, PS and NS systems, respectively, met IN51 criteria. These data indicate that evaluation of individual samples yields a lower percent of conformity with IN51 standards than tank samples. This implies that the milk from healthy cows may dilute the higher SCC of diseased cows, suggesting that tank samples are not accurate for a confident milk quality indicator. The fat, protein and total solids content in the tank samples were similar among the three production systems. Average lactose and urea nitrogen content in tank samples were similar between seasons. In contrast, the average SCC was above the IN51 standard in the tank and indiv...
The aim of this study was to compare the sperm separation technique using filtration through glass wool compared with just diluted cooled semen. Eighteen ejaculates were collected from 6 pony stallions of the Brazilian pony breed. Evaluations were done on pH, osmolarity, total motility, membrane functionality (HOST), membrane integrity (CFDA/PI), morphology and mitochondrial viability (MTT) in fresh, 24 and 48 h of cooled semen at 5°C. After dilution, the half of the extended semen was cooled (control group). The other half was cooled after filtration trough glass wool (filtered group). Retained semen was considered the portion of cells that did not transpose glass wool barrier. Total motility from the control, filtered and retained groups after 24 h of cooling was 35.5%, 43.3% and 10% (p < .0001) respectively. Sperm membrane integrity percentage at the CFDA/PI test was 37.9%, 44.8% and 14.8% (p < .0001), on the control, filtered and retained groups respectively. The results confirmed that the passage of spermatozoa through glass wool increased the selection of spermatozoa from pony stallions with higher motility, mitochondrial viability and membrane integrity for cooling in milk extender up to 24 h. Moreover, it was not obtained higher sperm parameters to control after cooling 48 h under the conditions that the study was conducted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.