To study the possible influence of mechanical ventilation on the accuracy of thoracic electrical bioimpedance (TEI) in the measurement of cardiac output, we determined cardiac output concurrently by TEI using Kubicek's equation and by thermodilution in 8 acutely ill patients who were mechanically ventilated (assist/control mode) but who had no underlying respiratory failure. Cardiac outputs were lower with TEI than with thermodilution (3.97 +/- 0.80 vs 4.83 +/- 1.16 l/min p = 0.004) and there was poor correlation between the values (r = 0.41). Although there is a need to develop non-invasive techniques to measure cardiac output, the present study indicates that TEI is not reliable in mechanically ventilated patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.