The aim of this study was to assess the accuracy of protected telescoping catheter performed using: 1) protected distal aspiration, or 2) protected mini-bronchoalveolar lavage for the diagnosis of ventilator-associated bacterial pneumonia. Twenty-seven patients who died after receiving mechanical ventilation for at least 72 h were included in a comparative prospective post-mortem study. The two microbiological sampling procedures were performed immediately after death. Surgical pneumonectomies and biopsies were performed within 30 min of death at the bedside for histological examination. The results of the two techniques were compared with histological post-mortem lung examination or biopsies. Histological examination of the parenchyma showed signs of pneumonia in 14 cases. Lung tissue culture was positive in nine of these 14 cases. When ventilator-associated bacterial pneumonia was defined by the association of histological signs and positive lung tissue culture the sensitivity was 78% for both sampling techniques, specificity was 86% for mini-bronchoalveolar lavage and 100% for protected distal aspiration (at a threshold of 1 x 10(3) cfu x mL(-1)). Both techniques protected the distal aspiration and mini-bronchoalveolar lavage, and provided good specificity with an acceptable sensitivity for the diagnosis of ventilator-associated bacterial pneumonia.
These results suggest that it is possible to obtain a further improvement in oxygenation by increasing AB infusion rate in ARDS patients iNO responders receiving norepinephrine. Due to the potential deleterious effects of AB, this strategy should be used in the most severely hypoxaemic patients.
Continuous monitoring of mixed venous (SvO2) and central venous (ScO2) oxygen saturation was compared in 7 critically-ill patients (Apache II score: 19 +/- 2.1) to determine whether or not information derived from ScO2 were reliable in clinical practice. Patients were catheterized with both a pulmonary artery (PA) and a central venous (CV) catheter, each of them mounted with fiberoptic sensors (Opticath PA Catheter P7110 and Opticath CV Catheter U440, Abbott). A total of 580 comparative measurements were obtained during periods without and with therapeutic interventions (drug-titration, bronchial suction, use of PEEP, changes in FiO2 ...). The systematic error between the 2 measurement techniques was 0.6% and 0.3% in periods with and without therapeutic interventions, respectively. The variability between the 2 techniques was 10% for both periods. Differences between the values were greater than or equal to 5% in 49% of values during periods of stability and in 50% of values during periods with therapeutic interventions. There were poor correlations between the values during periods without (r = 0.48) and with therapeutic interventions (r = 0.62). Better, but still less than ideal, correlations were obtained with changes in SvO2 and ScO2 during periods without (r = 0.70) and with therapeutic interventions (r = 0.77). Although there is a need to develop a simple technique to monitor mixed venous oxygen saturation, the present study indicates that ScO2 monitoring was not reliable in the study patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.