Forty-three mothers who had requested regional anaesthesia for elective Caesarean section were allocated randomly to receive either extradural anaesthesia with pH-adjusted 2% lignocaine with 1/200,000 adrenaline, or incremental spinal anaesthesia using a 32-gauge catheter with 0.5% plain bupivacaine. Increments of lignocaine or bupivacaine were given with the aim of achieving a block from T4 to S5. The spinal catheter was quicker to place (median 3 min, range 1-45 min, compared with median 10 min, range 1.5-50 min) and spinal anaesthesia was quicker to establish (median 20 min, range 10-46 min compared with median 48 min, range 15-59 min) compared with the extradural technique. The maximum height of the spinal block was significantly higher (median T3-4, range T5-T3) than the extradural group (median T5, range T6-T3). The total dose of intrathecal 0.5% bupivacaine was unpredictable, with a mean dose of 2.7 ml and a range between 1.5 ml and 7.4 ml. Haemodynamic stability and the quality of the block were similar between the groups. There were two mild spinal-headaches in the spinal group. All the spinal catheters were removed intact.
Twenty mothers who had requested regional analgesia during labour had a 32-gauge catheter inserted into the lumbar subarachnoid space. The mean time to place the catheters was 116 s (range 55-270 s) and there were no technical difficulties. Incremental diamorphine was given, up to a maximum initial dose of 0.5 mg. Analgesia was excellent in 11 mothers, good in seven and unsatisfactory in two. The duration of initial analgesia from diamorphine was 101 min (range 30-170 min). Eight mothers were able to move about during the first stage, with effective analgesia. Side effects were common: 15 mothers had pruritus, 15 had nausea or vomiting, and eight had mild sedation. No mother had a ventilatory frequency of less than 12 b.p.m. in the 12 h after the last dose of intrathecal diamorphine. Intrathecal 0.5% bupivacaine was given to 16 mothers in the first stage because the analgesia after a top-up with diamorphine became insufficient later in the labour. Fifteen mothers were pain free after bupivacaine; there was one failure. The initial effective dose of bupivacaine was between 0.25 ml and 2 ml. The maximum height of the block after bupivacaine was T9, and there was no hypotension. Nine mothers were given hyperbaric 0.5% bupivacaine 1-2 ml during the second stage; all were pain free for the procedure. The maximum force needed to withdraw the catheters was 700 g; and all catheters were removed intact. There were no post-spinal headaches.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.