To guarantee evacuation time and prevent the spread of fire and the collapse of a building on fire, the main structure is designed based on the fire resistance construction, depending on the number of stories, the purpose, and the scale of the building. Further, the fire resistance construction plan is designed using prescriptive or performance methods. Domestic laws prescribe materials and recommend certain thickness of fire resistance constructions, without considering the fire-resistant performance time. Issues such as over-design or under-design and lack of consideration of the recent technological advancements in construction materials and techniques persist, as considerable time would have elapsed since the enactment of the law. Therefore, the purpose of this study is to make improved modifications to the Building Code for Fire resistance Construction prescribed in Article 3 of the current "Rules for the Standards of Escapes/ Fire-Proof Construction of Buildings and Others."
This study aimed to elucidate the thermal safety of precision pulse capsulotomy (PPC) via in vivo and in vitro evaluation of the thermal profile using infrared thermography.Methods: This prospective observational study enrolled 15 eyes from 15 participants who underwent cataract surgery using the Zepto PPC. All patients underwent temperature measurements of the incision site and the entire cornea using an infrared thermographer during the capsulotomy procedure.To accurately analyze the temperature change of the Zepto PPC, infrared thermography was performed with the Zepto handpiece while exposed to air and then in porcine eyes. Moreover, in each case, the difference in temperature change according to the use of an ophthalmic viscosurgical device (OVD) was also checked to determine the temperature buffering effect.Results: In the clinical evaluations, the mean temperature elevation around the corneal incision and time duration from baseline to peak temperature during the Zepto capsulotomy were 4.0 ± 1.9℃ and 4.43 ± 1.26 s, respectively, with a mean peak temperature of 32.6 ± 2.0℃. The mean peak temperature and rise time of the naïve Zepto nitinol ring, as measured from the bottom side, were 109.0 ± 22.9℃ and 43.40 ± 11.06 s in the experimental procedures, respectively. In the porcine eyes, the mean elevation of temperature and rise time of the Zepto nitinol ring were 6.2 ± 1.6℃ and 11.67 ± 2.08 s with the use of OVDs, and 10.5 ± 3.3℃ and 14.00 ± 3.61 s without OVDs, respectively.
Conclusions:Zepto PPC has the potential to generate extremely high thermal energy, according to an in vitro study. However, the temperature rise of the Zepto capsulotomy can be minimized by using OVDs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.