The mechanical design considerations of the CW352 two shaft industrial type gas turbine are discussed with emphasis on achieving a high degree of mechanical reliability based on the extensive service experience of the company’s mature 1450°F inlet machines. Problem areas of the early units are discussed and how avoidance of problems has been considered in the design of the CW352.
Article citation info: (*) Tekst artykułu w polskiej wersji językowej dostępny w elektronicznym wydaniu kwartalnika na stronie www.ein.org.pl KorTA J, SKruch P. The concept of integrating vapor chamber into a housing of electronic devices for increased thermal reliability.
The CW352 two shaft industrial type gas turbine was first put in commercial service in 1979. By mid 1985 units in simple cycle and regenerative modes have accumulated in excess of 200,000 hrs. of operation, with lead units in excess of 50,000 hrs. simple cycle mode and 35,000 hrs. in regenerative cycle mode. The paper discusses the operational experience with emphasis on early field problems and their solutions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.