We have devised a simple, fast and efficient method to optimize the number and position of catheters in HDR brachytherapy. Ultimately, this catheter optimization algorithm could be coupled with a 3D ultrasound system to allow real-time guidance and planning for any interstitial brachytherapy sites.
The purpose of this paper is to evaluate the dosimetric capabilities and the radiation protection (RP) performance of a new automatic needle‐loading system for permanent prostate implants, the Isoloader (Mentor Corp.). The unit has been used in more than 100 clinical cases at our institution.The Isoloader is a computerized workstation that allows automated seed testing by a solid‐state CdZnTe radiation detector and loading in surgical needles. The seeds are received in a shielded and ready‐to‐use cartridge. Radiation protection measurements were done on a cartridge filled with 67 I125 seeds and during dosimetric seed verification and needle loading. The reproducibility of the detector was tested and its accuracy was determined by comparison to specified activities of six calibration seeds and to their measurements in a calibrated well‐chamber (WC). Finally, the times required to complete dosimetric verification and needle loading were evaluated.The cartridge was found to be adequately shielded, since no significant amount of radiation was detected around it. Radiation during seed assay was found to be worst at the cartridge's bottom, where it has a value of 15.2 μSv/h (1.4 μSv/h at 10 cm). For the needle‐loading task, measurements were performed with a typical needle (three seeds) at the shielded needle holder surface yielding
307.2 μSv/h (8.3 μSv/h at 20 cm). Seed dosimetric verification takes an average of 15 s/seed, while it takes a mean time of 50 s/needle to complete the loading task. Measurements of the six seed activities were within 0.65% of the ordered activities and 1.9% higher on average than those from the WC (min=0.7%;max=3.5%). The reproducibility of the measurements of the CdZnTe detector was excellent, with an average of 0.01% of deviation from a reference measurement (N=120;σ=1.9%).We therefore conclude that the Isoloader is a safe, fast, and effective needle‐loading system.PACS number: 87.53.Jw
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.