Primary angle closure glaucoma (PACG) is a major cause of blindness worldwide. We conducted a genome-wide association study (GWAS) followed by replication in a combined total of 10,503 PACG cases and 29,567 controls drawn from 24 countries across Asia, Australia, Europe, North America, and South America. We observed significant evidence of disease association at five new genetic loci upon meta-analysis of all patient collections. These loci are at EPDR1 rs3816415 (odds ratio (OR) = 1.24, P = 5.94 × 10(-15)), CHAT rs1258267 (OR = 1.22, P = 2.85 × 10(-16)), GLIS3 rs736893 (OR = 1.18, P = 1.43 × 10(-14)), FERMT2 rs7494379 (OR = 1.14, P = 3.43 × 10(-11)), and DPM2-FAM102A rs3739821 (OR = 1.15, P = 8.32 × 10(-12)). We also confirmed significant association at three previously described loci (P < 5 × 10(-8) for each sentinel SNP at PLEKHA7, COL11A1, and PCMTD1-ST18), providing new insights into the biology of PACG.
The iCare HOME tonometer is a useful tool which can be used by patients for fairly accurate and reliable self-measurement of intraocular pressure (IOP).Purpose: The aim was to compare the accuracy of IOP measurements of trained glaucoma patients using the iCare HOME tonometer before and after a week of self-monitoring at home and study the repeatability of patient measurements done at home. Materials and Methods:A total of 40 glaucoma patients had IOPs measured using the Goldmann applanation tonometer and the iCare HOME. Patients were trained to use the iCare HOME and measured their IOP twice daily over a loan period of 7 days. Bland-Altman analysis was used to assess agreement between Goldmann applanation tonometer and iCare HOME readings. Intraclass correlation coefficient compared inter-rater reliability of iCare HOME measurements, and test-retest variability for the patient's readings over the 7-day period were analyzed. A 5-point Likert scale questionnaire was used to assess the patient's experience with the device.Results: Up to 32 patients (80%) were able to obtain IOP readings within 3 mm Hg of the glaucoma nurse clinician's readings at the preloan visit, and up to 36 patients (90%) at the postloan visit. Good inter-rater reliability was observed between iCare HOME measurements by the glaucoma nurse clinician and patients. At the postloan visit, inter-rater reliability was good for right eye readings and excellent for left eye readings. No distinct trend in test-retest variability was identified over the 7-day period. 65% of patients agreed the device was easy to use and 89% would recommend the device to other glaucoma patients. Conclusion:Patients trained to use the iCare HOME device can do so with fair accuracy compared with trainers with accuracy improving within 1 week of usage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.