Objective
To compare our experience with pedicle screw insertion of the thoracolumbar spine utilizing the Cirq robot assistance device compared with traditional paradigm using fluoroscopy.
Methods
We prospectively collected data of patients undergoing pedicle screw instrumentation in the thoracolumbar spine performed by a single surgeon at three different centers. One center took delivery of the Cirq robotic assistance device. Remaining two centers used C-arm fluoroscopy. Demographic information, diagnosis, total OR time, intraoperative complications, unexpected return to the operating room, and hospital readmissions within 90 days was compared between the two cohorts.
Results
A total of 166 screws were placed during the study period. Forty percent were placed using the Cirq. Two thirds the patients had traumatic diagnoses with remaining degenerative spine disease. There were no misplaced pedicle screws in either group. While total OR time was longer in the Cirq cohort by 123 min (p = 0.04), actual procedural time was not statistically different (p = 0.11). Nonetheless there were also more hospital readmissions in the Cirq cohort compared with the C arm group (p = 0.04).
Conclusions
Thoracolumbar screws inserted using C-arm fluoroscopy utilize less total operating room time with similar accuracy compared with the Cirq robotic assistance device. Further studies are warranted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.