We performed a national postal survey exploring anaesthetists' practice in rapid sequence induction. All respondents used pre-oxygenation, although the technique employed, and its reliability, varied. Thiopental and succinylcholine, given after waiting for signs of loss of consciousness, were the most widely used drugs for rapid sequence induction. Propofol and rocuronium were used by more than a third of respondents, and most respondents (75%) also routinely administered an opioid. Cricoid pressure was used universally but the practice of its application varied widely. The commonest aids used if intubation was difficult were the gum elastic bougie, the long laryngoscope blade and the laryngeal mask. After failed intubation, approximately half of respondents would maintain the supine position. Failure to intubate at rapid sequence intubation had been seen by 45% of respondents but harm was uncommon. In contrast, 28% had seen regurgitation, which frequently led to considerable harm and to three deaths. In spite of this, practice of a failed intubation drill was uncommon (15%) and anaesthetic assistants were rarely known to practice application of cricoid pressure. Consultants were less likely than trainees to use rocuronium as a muscle relaxant, and more likely to choose morphine if administering an opioid. They were less likely to practice a failed intubation drill. Other aspects of practice varied little between grades. This survey suggests that many anaesthetists do not follow best practice when performing a rapid sequence induction.
We performed a national postal survey exploring anaesthetists' practice in rapid sequence induction. All respondents used pre‐oxygenation, although the technique employed, and its reliability, varied. Thiopental and succinylcholine, given after waiting for signs of loss of consciousness, were the most widely used drugs for rapid sequence induction. Propofol and rocuronium were used by more than a third of respondents, and most respondents (75%) also routinely administered an opioid. Cricoid pressure was used universally but the practice of its application varied widely. The commonest aids used if intubation was difficult were the gum elastic bougie, the long laryngoscope blade and the laryngeal mask. After failed intubation, approximately half of respondents would maintain the supine position. Failure to intubate at rapid sequence intubation had been seen by 45% of respondents but harm was uncommon. In contrast, 28% had seen regurgitation, which frequently led to considerable harm and to three deaths. In spite of this, practice of a failed intubation drill was uncommon (15%) and anaesthetic assistants were rarely known to practice application of cricoid pressure. Consultants were less likely than trainees to use rocuronium as a muscle relaxant, and more likely to choose morphine if administering an opioid. They were less likely to practice a failed intubation drill. Other aspects of practice varied little between grades. This survey suggests that many anaesthetists do not follow best practice when performing a rapid sequence induction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.