Bacteriophage MS2 is used in place of pathogenic viruses in a wide variety of studies that range from testing of compounds for disinfecting surfaces to studying environmental transport and fate of pathogenic viruses in groundwater. MS2 is also used as a pathogen simulant in the research, development, and testing (including open air tests) of methods, systems, and devices for the detection of pathogens in both the battlefield and homeland defense settings. PCR is often used as either an integral part of such detection systems or as a reference method to assess the sensitivity and specificity of microbial detection. To facilitate the detection of MS2 by PCR, we describe here a set of real-time fluorogenic reverse transcription-PCR assays. The sensitivity of the assays (performed with primer pairs and corresponding dye-labeled probes) ranged from 0.4 to 40 fg of MS2 genomic RNA (200 to 20,000 genome equivalents). We also demonstrate the usefulness of the primer pairs in assays without dye-labeled probe that included the DNA-binding dye SYBR green. None of the assays gave false-positive results when tested against 400 pg of several non-MS2 nucleic acid targets.
Public reporting burden for this collection of infonnation is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing this collection of infonnation. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggesttons for reducing this burden to Department of Defense, Washington Headquarters Services, Directorate for Information Operattons and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be avrare that notwithstanding any cither provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid 0MB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS.
Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing this collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.