ObjectivesThe aim of this study was to determine the relationship of ovarian volume (OV) to age, height, and weight in Korean young women with the polycystic ovary syndrome (PCOS) undergoing ultrasonography (US) and to investigate the relationship between ovarian follicle count and volume on US and serum hormone levels including the levels of the anti-Müllerian hormone (AMH) and gonadotropin.MethodsA total of 272 Korean nulliparous women aged 15 to 39 years who were newly diagnosed with PCOS at a university hospital were included in this study. Evaluation of the ovaries and measurement of OVs in all cases were randomly performed by ultrasound. The OV and follicle number (FN) were obtained in all cases.ResultsIn Korean women with PCOS, mean OV was 7.9 ± 3.6 cm3 (right) and 6.7 ± 3.1 cm3 (left). Mean FN in the PCOS group was 14.2 ± 4.6 (right) and 13.8 ± 4.3 (left). OV and ovarian FN were unrelated to patient weight, height and body mass index. The left ovarian FN was related to patient age. AMH levels ranged from 5.31 to 43.1 ng/mL and the mean level was 13.9 ± 7.2 ng/mL. Serum AMH was related to OV and FN, and serum total testosterone was related to FN in Korean women with PCOS.ConclusionsIn Korean nulliparous women with PCOS, OV was smaller than that in other ethnic groups and the right OV was larger than the left OV. Ovarian FN, AMH, testosterone are good markers for the diagnosis of PCOS in Korean women.
In recent years, silver nanoparticles (AgNPs) have been extensively employed in food packaging systems as a potential antibacterial agent. Although proven to be highly effective, the increased number of AgNP-containing products raises concerns among consumers regarding the migration of AgNPs from the packaging material into foods, which may exert toxic effects. To address this, five baby products were chosen (baby bottle A, baby bottle B, pacifier A, pacifier B and breastmilk storage bag) to investigate AgNPs migration into three food simulants (deionised water, 4% acetic acid (w/v) and 50% ethanol (v/v)) using inductively coupled plasma mass spectrometry (ICP-MS). As a result, the highest level of migrated Ag was observed for 4% acetic acid in the case of baby bottle B, pacifier A, pacifier B and the breastmilk storage bag, with the detection amount ranging from 1.05-2.25 ng/mL. On the other hand, baby bottle A showed the maximum migration for 50% ethanol due to the polymer nature. Finally, a centrifugal ultrafiltration experiment was conducted to determine the fraction of dissolved Ag in acidic simulant and it was found that migrated Ag was predominantly in Ag form, with a small fraction of non-ionic AgNPs. Thus, it has been found that the amount of migrated Ag in baby products was low; however, the migration was dependent on the type of food simulant and polymer nature.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.