Aiming at the shortcomings of current transmission line state evaluation, which refers to the isolation of scalars and the low accuracy of evaluation methods, a transmission line state evaluation technology based on multi-source parameter fusion is proposed. This paper collects and selects characteristic data such as line test inspection information, operation and maintenance records, and power grid operating parameters as indicator quantities. The membership function is used to express the distribution state of the index quantity, and the distribution state is used as the data to establish a comprehensive evaluation model of the line operation state based on the long- and short-term memory network. The data tag is used to train the deep network to establish the mapping relationship between index parameters and operation state. Experiments show that the evaluation accuracy of the proposed method is significantly higher than that of the traditional shallow method, which can provide theoretical guidance for the operation and maintenance of overhead transmission lines.
Aiming at the problem of low accuracy of traditional methods in transmission corridor line safety monitoring, a transmission corridor line safety monitoring method based on monocular vision is designed. First of all, this article defines the target object of the safety monitoring of the transmission corridor line. Then, based on the monocular vision measurement to obtain the internal parameters of the camera geometry, optical characteristics, etc., the position of the power transmission corridor line security surveillance camera is calibrated, the power transmission corridor line security monitoring graphics are displayed, and the security monitoring data of the transmission corridor line is used for perception and track.Finally, the safety monitoring and early warning of transmission corridor lines are realized. The experimental results show that the monitoring accuracy of the design method is significantly higher than that of the control group, which can solve the problem of low accuracy of transmission corridor line safety monitoring by traditional methods.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.