Despite the international trend of actively utilizing BIM in the field of energy simulation, it is difficult to actively utilize BIM in domestic certification-related practice. As a result, the work process is not integrated and the work efficiency is reduced, such as the occurrence of redundant tasks. In this paper, the integrated process based on the BIM geometry information automated extraction module was presented and its effectiveness was reviewed and verified through self-developed automation module and uniformity and error-causing analysis. The construction of an integrated process through automatic configuration information extraction has the advantages of reducing the workload, enabling additional tasks through module function expansion, sharing information through the web, and ease of service manufacture. In addition, an experiment comparing the data of automatic and manual calculations with three subjects confirmed that automatic calculation database through automation module can produce a more reliable and uniform database with a lower proportion of human error than the manual calculation module. This not only improves the reliability of the energy simulation itself, but also reduces the human and temporal loads that occur during the post-simulation data verification process.
As one of the energy saving policies, the Korean government has been regulating the indoor thermal environment of public office facilities in Korea, starting with energy conservation measures in 1980. This policy, which is above 28 °C in summer and below 18 °C in winter, is causing discomfort among the occupants. The purpose of this study is to support the need to improve temperature limitation standards of the Korean public office facilities. For this purpose, the standards for the thermal environment in offices of major countries and associations were examined. Subsequently, they were compared with the Korean standards. Additionally, nine buildings of public office facilities in Korea were surveyed on the thermal environment, and PMV measurement was carried out. As a result, most of the buildings that complied with the cooling temperature standard as well as most of the buildings that did not comply were found to be uncomfortable. In conclusion, to improve the comfort of Korean public office facilities in the heating and cooling period, it is necessary to mitigate temperature regulation and regulate additional environmental factors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.