Chromaticity of cigarette industry wastewater increase when treating by aerobic due to large quantities of lignin, nicotine and carbohydrate. Ozone and advance oxidation are proposed for degradation and decoloration of cigarette wastewater that processed by aerobic. The result shows that ozone process has its advantage of high decoloration rate, simple operation and low operation cost. Optimum parameters of ozone process are ozone dosage of 37.65mg/L, reaction time of 15min, reaction pH of 7.0-9.0. The COD removal rate is 38.3% when the decoloration rate is 57.5%. Operation cost of ozone process is 0.4 yuan/m3.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.