Background: Arterial blood pressure is one of the most commonly variables monitored during anesthetic procedures in veterinary patients. The most reliable method for measuring arterial blood pressure in dogs and cats is the direct (invasive) method. However, the oscillometric method is less complex and more practical for clinical routine in small animals. Nevertheless, oscillometric monitors present great variability in accuracy. The present study aimed to determine the accuracy of the Delta Life DL 1000 oscillometric monitor for measurement of systolic, mean and diastolic blood pressures (SAP, MAP and DAP, respectively) in anesthetized dogs of different weight ranges.Materials, Methods & Results: This study was approved by the Institutional Ethics Committee of Animal Use. Fifteen female dogs of different breeds, weighing 11.6 ± 10.0 kg and with a mean age of 48 ± 51 months were used. All animals were scheduled for elective surgery under general anesthesia in the Institution Veterinary Hospital. Dogs were anesthetized with morphine, propofol and isoflurane and had one 20 or 22 gauge catheter introduced into the dorsal pedal artery for continuous, invasive monitoring of SAP, MAP and DAP. A blood pressure cuff was positioned over the middle third of the radius and connected to Delta Life DL 1000 monitor. Oscillometric readings of SAP, MAP and DAP were registered every 5 minutes, and invasive values were simultaneously recorded. Values obtained with both methods were compared (invasive versus oscillometric) by use of the Bland Altman method to determine the bias, standard deviation of bias and 95% limits of agreement. The percentages of errors between the methods within 10 mmHg and within 20 mmHg were calculated. The results obtained were compared with the criteria from the American College of Veterinary Internal Medicine (ACVIM) for validation of indirect methods of arterial blood pressure measurement. Data were stratified into two groups according to the weight: < 10 kg (Group 1; n = 9); and ≥ 10 kg (Group 2; n = 6). In Group 1, 119 paired measurements were obtained, four of which classified as hypotension (SAP < 90 mmHg), 98 as normotension (SAP from 90 to 140mmHg) and 17 as hypertension (SAP > 140 mmHg). Bias (± SD) values in Group 1 were as follows: SAP, 5.2 ± 18.1 mmHg; MAP, -3.4 ± 17.2 mmHg; and DAP, 12.0 ± 17.5 mmHg. The percentages of errors within 10 mmHg were 40.3% for SAP; 45.4% for MAP and 28.6% for DAP. The percentages of errors within 20 mmHg were 72.3% for SAP, 84.0% for MAP and 68.1% for DAP. In Group 2, 66 paired measurements were obtained, nine of which classified as hypotension, 56 as normotension and one as hypertension. Bias (± SD) in Group 2 were as follows: SAP, 13.6 ± 14.3 mmHg; MAP, -1.1 ± 13.5 mmHg; and DAP, 8.2 ± 16.0 mmHg. The percentages of errors within 10 mmHg were 33.3% for SAP, 77.3% for MAP and 33.3% for DAP. The percentages of errors within 20 mmHg were 65.1% for SAP, 92.4% for MAP and 83.4% for DAP.Discussion: Based on the results of this study and reference criteria from the ACVIM, the Delta Life DL 1000 monitor had a poor accuracy for SAP, MAP and DAP and did not meet the criteria from the ACVIM in anesthetized dogs under 10 kg. Measurements of MAP in dogs ≥ 10 kg met the ACVIM criteria, but measurements of SAP and DAP did not. Based on the findings in this study, the DL 1000 oscillometric monitor is not recommended for blood pressure measurement in anesthetized dogs < 10 kg. In dogs ≥ 10 kg, measurements of MAP yielded acceptable values, but SAP and DAP measurements did not.
Background: The oscillometric monitor is a noninvasive method used for measuring blood pressure in dogs and cats. Despite widely used, there is a large variability in the accuracy of oscillometric monitors, which may also be influenced by the location of the blood pressure cuff. The Doppler ultrasound is another non-invasive method that was shown to measure blood pressure with good accuracy and precision in small animals. The present study aimed to determine the agreement between systolic arterial pressure (SAP) measured by the Prolife P12 oscillometric monitor with two cuff locations and the Doppler ultrasound in anesthetized dogs.Materials, Methods & Results: Dogs scheduled for routine anesthetic procedures were included in the study, which was carried out in two phases. In Phase 1, SAP values measured by the Doppler were compared with those measured by the Prolife P12 monitor with the cuff placed at the thoracic limb for both methods. In Phase 2, SAP values measured by the Doppler were compared with those measured by the Prolife P12 monitor, with the cuff placed at the thoracic limb for the Doppler and at the base of the tail for the P12. The cuff width corresponded to approximately 40% of limb or tail circumference. On all occasions, three consecutive measurements of SAP were recorded, followed by a single measurement of SAP by the P12, and then other three measurements were performed with the Doppler. The arithmetic mean of the six SAP measurements with the Doppler was compared with the SAP value measured by the P12 monitor (paired measurements). Agreement between SAP values measured by the Doppler and the P12 monitor was analyzed by the Bland Altman method for calculation of the bias (Doppler – P12) and standard deviation (SD) of the bias. The percentages of differences between the methods with an error ≤ 10 mmHg and ≤ 20 mmHg and Pearson’s correlation coefficients were also calculated. Results were compared with the criteria from the American College of Veterinary Internal Medicine (ACVIM) for validation of noninvasive blood pressure methods. A total of 33 dogs were included in Phase 1 and 15 were included in Phase 2. During Phases 1 and 2, 179 and 87 paired measurements were recorded, respectively. Most of the measurements were recorded during normotension (SAP = 90-130 mmHg): 113/179 in Phase 1 and 52/87 in Phase 2. The bias (± SD) for Phases 1 and 2 were -2.7 ± 14.1 mmHg and 7.2 ± 25.8 mmHg. The percentages of differences ≤ 10 mmHg and ≤ 20 mmHg were: Phase 1, 61% and 83%; Phase 2, 41% and 70%. Correlation coefficients were 0.81 and 0.67 for Phases 1 and 2, respectively. According to the ACVIM criteria, maximum values accepted for bias are 10 ± 15 mmHg, the percentages of differences ≤ 10 mmHg and ≤ 20 mmHg should be ³ 50% and ³ 80%, respectively, and the correlation coefficient should be ³ 0.9. Discussion: When the blood pressure cuff was placed at the thoracic limb, SAP values measured by the P12 monitor met most of the ACVIM criteria, demonstrating good agreement with SAP values measured by the Doppler. The only requirement not met was the correlation coefficient which was 0.81 whereas the recommended is ³ 0.9. Conversely, when the cuff was placed at the base of the tail, SAP values measured by the P12 monitor did not meet most of the ACVIM criteria indicating that, in anesthetized dogs, SAP measurements with the P12 monitor should be performed with the cuff placed at the thoracic limb. One limitation of this study was that most measurements fell in the normotensive range and the results should not be extrapolated for hypotensive and hypertensive conditions. In conclusion, the Prolife P12 oscillometric monitor demonstrated good agreement with SAP values measured by the Doppler and provides acceptable values in normotensive anesthetized dogs.Keywords: arterial blood pressure, nonivasive blood pressure, anesthetic monitoring.Título: Pressão arterial sistólica em cães anestesiados - concordância entre mensurações por dois métodos não invasivosDescritores: pressão arterial, pressão arterial não invasiva, monitoração anestésica.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.